Global Trade · Reliable Power Solutions E-mail: [email protected]
Industrial Control › S Series

SP-500W SP SERIES SWITCHING POWER SUPPLY WITH PFC

Features: • UniversalACinput/Fullrange • Built-in active PFC function, PF>0.95 • Protections:Short circuit/Over load/Over voltage/Over temp…

  • Category: Industrial Control › S Series
  • Model: chance_290
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this S Series

About the SP-500W SP SERIES SWITCHING POWER SUPPLY WITH PFC

The SP-500W SP SERIES SWITCHING POWER SUPPLY WITH PFC is part of the ELEHPD S Series range. Features: • UniversalACinput/Fullrange • Built-in active PFC function, PF>0.95 • Protections:Short circuit/Over load/Over voltage/Over temperature • Forced air cooling by built-in DC fan • Built-in cooling Fan ON-OFF control • Built-in remote ON-OFF control • Built-inremotesensefunction • Fixed switching frequency at 110KHz • 2 years warranty ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Full catalogue description: SP SERIES SWITCHING POWER SUPPLY WITH PFC FUNCTION SP-500W

Typical applications

How to specify the right S Series

  1. Size the contact rating for the inductive load, not just the resistive current (AC-3 duty for motors)
  2. Check the coil voltage and frequency available in the panel: 24 V DC, 110 V, 230 V or 400 V AC
  3. Confirm the auxiliary contact count needed for the control and indication circuit
  4. Match the enclosure rating to the environment (IP20 inside a panel, IP65 on the machine)

Specifications


SP SERIES SWITCHING POWER SUPPLY WITH PFC FUNCTION SP-500W

Features :

• UniversalACinput/Fullrange

• Built-in active PFC function, PF>0.95

• Protections:Short circuit/Over load/Over voltage/Over temperature

• Forced air cooling by built-in DC fan

• Built-in cooling Fan ON-OFF control

• Built-in remote ON-OFF control

• Built-inremotesensefunction

• Fixed switching frequency at 110KHz

• 2 years warranty


Model Specification SP-500-12 SP-500-13.5 SP-500-15 SP-500-24 SP-500-27 SP-500-48
DC output voltage 12V 13.5V 15V 24V 27V 48V
Output voltage error ±1% ±1% ±1% ±1% ±1% ±1%
Rated output current 40A 36A 32A 20A 18A 10A
Output current rage 0-40A 0-36A 0-32A 0-20A 0-18A 0-10A
Wave and noise 240mVp-p 240mVp-p 240mVp-p 240mVp-p 200mVp-p 300mVp-p
Inlet stability ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load stability(Note5) ±1% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
DC output power 480W 486W 480W 480W 486W 480W
Efficiency 84% 84% 83% 85.5% 86.5% 87%
Adjustable range for DC voltage 10-13.2V 12-15V 13.5-18V 20-26.4V 24-30V 41-56V
AC input voltage range 88132VAC/176264VAC BY SWITCH 4763Hz;124370VDC
AC Input current 7A/115V 3.5A/230V
Power Factor 0.95/100240VAC
AC impulse current 18A/115V 36A/230V
Leakage current <3.5mA/240VAC
Overload protection 105%135% TypePULSING HICCUP SHUTDOWN Reset: auto recovery
Over-voltage protection 13.816.2V 15.518.2V 1821V 27.632.4V 3136.5V 57.667.2V
Fan control,O.T.P. RTH1 OR RTH2>=50 FAN ON,<=45 FAN OFF,>=70 Cut off output
Temperature coefficient ±0.03%(050)
Setup rise hold up time 1.5s,50ms,20ms
Vibration 10500Hz,2G 10min./1cycle,Period for 60min,EACH AXES
Withstand voltage Input and output interval3KVAC,Input and enclosure1.5KVAC Output and enclosure0.5KVAC
Isolation resistance Input and output interval,Input and enclosure,Output and enclosure500VDC/100M Ohms
Working temperature and humidity -10+50,20%90%RH
Store temperature and humidity -20+85,10%95%%RH
Overall dimension 185*20*93mm
Weight 1.8Kgs
Safety standards UL1950,TUV EN60950
EMC standards IEC1000-42,3,4,5,6,8,11 IEC100-3-2

Frequently asked questions about the SP-500W SP SERIES SWITCHING POWER SUPPLY WITH PFC

What is the difference between a contactor and a relay?

A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.

How do I calculate the correct contactor size for a motor?

Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.

Do you supply the coil voltage I need?

Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.

Are auxiliary contacts included?

Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.

Related S Series models