Electrical Items › Counter

JD86S Counter

JD86S Counter from the ELEHPD Counter range.

  • Category: Electrical Items › Counter
  • Model: 981
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this Counter

About the JD86S Counter

The JD86S Counter is part of the ELEHPD Counter range. JD86S Counter from the ELEHPD Counter range. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Typical applications

How to specify the right Counter

  1. Match the rated current to the circuit design current, then check the cable ampacity
  2. Pick the trip curve to the load: B for resistive/lighting, C for general mixed loads, D for motors and transformers
  3. Confirm the breaking capacity meets the prospective short-circuit current at the point of installation
  4. Verify the pole configuration (1P, 1P+N, 2P, 3P, 3P+N, 4P) against the system earthing arrangement

Specifications


JD862 SERIES COUNTER

 

  

                                   


◆ Main products: JD862(T)、JD862-4、JD862(B)、JD862A、JD862(K)、JD862(X) etc. Used for single-phase and three-phase meters.

◆ Product features: generally-structure design; complete transmission ratio; position of worm and worm gear can be adjusted when fixing.
Especially for type JD862(K), its friction moment and errors are both superior to covering international standard.

◆ Popular transmission ratio:

For single-phase

720series(rup)

720

1200

1440

1800

2400

3600

600series(rup)

600

1000

1200

1500

2000

3000

For three-phase

300(rup)

400

500

600

1000

2000

4500

◆ Mechanical burden:
Less than 1.0% on the basis of 220V,COSΦ=1.0 and 0.05Ib according to enterprise standard. This following chart shows the mechanical burden error tested by DD862(K) 5A 720rup register.

Frequently asked questions about the JD86S Counter

What is the difference between an MCB and an MCCB?

An MCB (miniature circuit breaker) is a DIN-rail device for final circuits, typically rated up to 125 A with a fixed trip curve. An MCCB (moulded case circuit breaker) is a larger device for main and sub-main distribution, usually 16 A to 1600 A, with adjustable thermal and magnetic settings and a higher breaking capacity. Use an MCB for branch circuits and an MCCB where you need adjustability or higher fault ratings.

How do I choose between a Type B, C and D trip curve?

Type B trips between 3 and 5 times rated current and suits resistive loads such as lighting and heaters. Type C trips between 5 and 10 times and is the general-purpose choice for socket circuits and mixed loads. Type D trips between 10 and 20 times and is used for loads with high inrush, such as motors, transformers and large LED drivers.

What does 6 kA breaking capacity mean in practice?

It is the maximum prospective short-circuit current the device can safely interrupt. 6 kA covers most domestic and light commercial installations. Where the transformer is close and the fault level is higher, specify 10 kA devices so the breaker still clears the fault without damage.

Can these devices be supplied with your own brand?

Yes. OEM branding, buyer-specific labels, custom carton print and private-model numbering can be arranged on qualified order volumes.

Related Counter models

Further reading