Global Trade · Reliable Power Solutions E-mail: [email protected]
Industrial Control › S Series

S series single output high walt with PFC

1000W Single output high walt switching power supply 12v 24v Specification

  • Category: Industrial Control › S Series
  • Model: chance_377
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this S Series

About the S series single output high walt with PFC

The S series single output high walt with PFC is part of the ELEHPD S Series range. 1000W Single output high walt switching power supply 12v 24v Specification ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Full catalogue description: S series single output high walt with PFC function SCN-1000w switching power supply 12V 24V SMPS

Typical applications

How to specify the right S Series

  1. Size the contact rating for the inductive load, not just the resistive current (AC-3 duty for motors)
  2. Check the coil voltage and frequency available in the panel: 24 V DC, 110 V, 230 V or 400 V AC
  3. Confirm the auxiliary contact count needed for the control and indication circuit
  4. Match the enclosure rating to the environment (IP20 inside a panel, IP65 on the machine)

Specifications


1000W Single output high walt switching power supply 12v 24v

Specification

Model SCN-1000-12 SCN-1000-15 SCN-1000-24 SCN-1000-48
Output DC output Voltage 12V 15V 24V 48V
Voltage tolerance ±1.0% ±1.0% ±1.0% ±1.0%
Rated Current 80A 66A 42A 20A
Related Power 1000w 1000w 1000w 1000w
Wave&Noise 240mVp-p 240mVp-p 240mVp-p 300mVp-p
Adjustable range for DC Voltage ±10% ±10% ±10% ±10%
Set up,rise,hold up time 200ms 100ms 30ms
Input Voltage Range 170-264VAC 47-63HZ
Input Current 7A/230VAC
Efficiency 83% 84% 85% 87%
AC inrush current Cold start current 50A /230VAC
Leakage current <3.5mA/240VAC
Protection Overload Related output power 105-150% start overload protection
Protection type: cutoff output, recovery after restart power
Over voltage 13.8V-16.2V 17.2V-20.2V 27.6V-32.4V 55V-64.8V
Hiccup mode,recovers automatically after fault condition
Environment Working temp humidity -10~+60°C 20%~90%RH
Stor temp, humidity -20~+85°C 20%~90%RH Non-condensing
Safety Withstand voltage I/P-O/P:1.5KVAC 1min
I/P-FG:1.5KVAC 1min
O/P-FG:0.5KVAC 1min
Standard Safety standard Fit UL1012
Refer Design refer to GB4943,UL60950,EN60950
EMC standard Design refer to GB9254,EN55022 Class A
Size size L238*W132*H68mm
Package 2.4kg, 4pcs/10kg


Frequently asked questions about the S series single output high walt with PFC

What is the difference between a contactor and a relay?

A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.

How do I calculate the correct contactor size for a motor?

Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.

Do you supply the coil voltage I need?

Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.

Are auxiliary contacts included?

Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.

Related S Series models