75W Single switching power supply 12v 24v 5v Features: • Universal AC input / Full range • Protections:Short circuit/Over load/Over voltage…
The 60W Single switching power supply 12v 24v 5v S-75W is part of the ELEHPD S Series range. 75W Single switching power supply 12v 24v 5v Features: • Universal AC input / Full range • Protections:Short circuit/Over load/Over voltage • Cooling by free air convection • 100% full load burn-in test • Fixed switching frequency at 77KHz • 2 years warranty ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
75W Single switching power supply 12v 24v 5v
Features :
• Universal AC input / Full range
• Protections:Short circuit/Over load/Over voltage
• Cooling by free air convection
• 100% full load burn-in test
• Fixed switching frequency at 77KHz
• 2 years warranty
| Model | S-75-12 | S-75-15 | S-75-24 | S-75-48 |
| DC output voltage | 12V | 15V | 24V | 48V |
| Rated output current | 6A | 5.0A | 3A | 1.5A |
| Output current range | 0-6A | 0-5A | 0-3A | 0-1.5A |
| Wave and noise | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
| Inlet stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Efficiency | 78% | 79% | 82% | 83% |
| Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% |
| AC input voltage range: | 85~132VAC/170~264VAC selected by switch 47~63Hz;240~370VDC | |||
| AC inrush current: | Cold-start current 15A/115V 30A/230V | |||
| Overload protection: | 105%~150% Type:plusing hiccup shutdown Reset:auto recovery | |||
| Setup rise hold-up time: | 200ms,50ms,20ms | |||
| Withstand voltage:Input and output internal: | 1.5KvAC,Output and enclosure:0.5KvAC | |||
| Isolation resistance: | Input and output internal,input and enclosure,output and enclosure:500VDC/100MΩ | |||
| Working temperature | 0~50°C | |||
| Safety standards: | GB4943 UL60950 EN60950 | |||
| EMC standards: | EN55022 GB9254,class A | |||
| Overall dimension: | 159*97*38mm | |||
| Weight: | 0.56Kgs |
OVERALL DIMENSION
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.