Global Trade · Reliable Power Solutions E-mail: [email protected]
Electrical Items › Switching Power Supply

S-100 Switching Power Supply

Low price and high reliability 105℃ output capacitor AC input power suitable for the world High efficiency and low operation temperature So…

  • Category: Electrical Items › Switching Power Supply
  • Model: 1003
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this Switching Power Supply

About the S-100 Switching Power Supply

The S-100 Switching Power Supply is part of the ELEHPD Switching Power Supply range. Low price and high reliability 105℃ output capacitor AC input power suitable for the world High efficiency and low operation temperature Soft-start current can reduce the AC input impact effectiely With short-circuit and owwerload protection 100% full-load burning test Installed with EMI filter,minimum wave ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Typical applications

How to specify the right Switching Power Supply

  1. Size the contact rating for the inductive load, not just the resistive current (AC-3 duty for motors)
  2. Check the coil voltage and frequency available in the panel: 24 V DC, 110 V, 230 V or 400 V AC
  3. Confirm the auxiliary contact count needed for the control and indication circuit
  4. Match the enclosure rating to the environment (IP20 inside a panel, IP65 on the machine)

Specifications


S-100 Switching Power Supply(Single Way)

  • Low price and high reliability
  • 105℃ output capacitor
  • AC input power suitable for the world
  • High efficiency and low operation temperature
  • Soft-start current can reduce the AC input impact effectiely
  • With short-circuit and owwerload protection
  • 100% full-load burning test
  • Installed with EMI filter,minimum wave
  • Model

    Performance
    S-100-3 S-100-5 S-100-7-5 S-100-12 S-100-15 S-100-24 S-100-27 S-100-48
    DC output voltage 3V 5V 7.5V 12V 15V 24V 27V 48V
    Output voltage error(Note:2) ±2% ±2% ±1% ±1% ±1% ±1% ±1% ±1%
    Rated output current 20A 20A 13.6A 8.5A 6.7A 4.5A 3.7A 2A
    Output current rage 0-20A 0-20A 0-13.6A 0-8.5A 0-6.7A 0-4.5A 0-3.7A 0-2A
    Wave and noise(Note:3) 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
    Inlet stability(Note:4) ±0.5% ±0.5% ±0.5% ±0.3% ±0.3% ±0.2% ±0.2% ±0.2%
    Load stability(Note:5) ±0.5% ±0.5% ±0.5% ±0.3% ±0.3% ±0.2% ±0.2% ±0.2%
    DC output power 60W 100W 102W 102W 100.5W 108W 99.9W 96W
    Efficiency 70% 78% 80% 81% 81% 84% 84% 84%
    Adjustable range for DC voltage 2.85-3.3V 4.75-5.5V 6.75-8.25V 10.8-13.2V 13.5-16.5V 21.6-26.4V 26-32V 43.2-52.8V
    Range for input votage 85~132VAC,170~264VAC,47~63HZ,switch choice
    Input current 2.4A/112V 1.2A/230V
    Impact current Cool-start current30A/115V 60A/230V
    Leakage current <1mA/240VAC
    Overload proctection 105~150% 150~200% 105~150%

    TYPE RESET:RECYCLE AC ON/OFF

    Over-voltage protection ……
    High-temperature protection ……
    Temperature factor ±0.03%℃(0~50℃)
    Start,rise and lock time 200ms,80ms,20ms
    Vibration resistance 10~500Hz,2G 10min./1cycle,time60,minutes for each shaft
    Resistance to pressure

    Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

    Insolationg resistance Input and output internal,input and enclosure,Output and enclosure:0500VAC/100M Ohms
    Operating temperature and humidity -10℃~+60℃,20%~90%RH
    Store temperature and humidity -20℃~+85℃,10%~95%RH
    Overall dimension 199*98*38mm
    Weight 0.5Kgs
    Safety standard Conform to requirement in UL1012
    EMC standard ……
    Note:1.The testing condition for the paramenter above is :230VAC input,rated load, 25℃ 70% RH.Humidity
       2.Error.include the setting error,line stability and load stability.(Note:5)
       3.Wave test:adopting A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
       4.Inlet voltage stability test:when is over load, the lowest voltage of inlet is up to the highest voltage.
       5.Load stability test:The load is from 0% to 100%

    Frequently asked questions about the S-100 Switching Power Supply

    What is the difference between a contactor and a relay?

    A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.

    How do I calculate the correct contactor size for a motor?

    Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.

    Do you supply the coil voltage I need?

    Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.

    Are auxiliary contacts included?

    Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.

    Related Switching Power Supply models

    Further reading