Global Trade · Reliable Power Solutions E-mail: [email protected]
Electrical Items › Thermal Relay

LR9-F Thermal Relay

SPECIFICATION Type Setting range For contactor LR9-200 30-50 F115-F185 48-80 F115-F185 60-100 F115-F185 90-150 F115-F185 132-220 F225-F265…

  • Category: Electrical Items › Thermal Relay
  • Model: 638
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this Thermal Relay

About the LR9-F Thermal Relay

The LR9-F Thermal Relay is part of the ELEHPD Thermal Relay range. SPECIFICATION Type Setting range For contactor LR9-200 30-50 F115-F185 48-80 F115-F185 60-100 F115-F185 90-150 F115-F185 132-220 F225-F265 LR9-630 200-330 F330-F500 300-500 F330-F500 380-630 F400-F630 ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Typical applications

How to specify the right Thermal Relay

  1. Size the contact rating for the inductive load, not just the resistive current (AC-3 duty for motors)
  2. Check the coil voltage and frequency available in the panel: 24 V DC, 110 V, 230 V or 400 V AC
  3. Confirm the auxiliary contact count needed for the control and indication circuit
  4. Match the enclosure rating to the environment (IP20 inside a panel, IP65 on the machine)

Specifications


SPECIFICATION

Type

Setting range

For contactor

LR9-200

30-50

F115-F185

48-80

F115-F185

60-100

F115-F185

90-150

F115-F185

132-220

F225-F265

LR9-630

200-330

F330-F500

300-500

F330-F500

380-630

F400-F630

 

Frequently asked questions about the LR9-F Thermal Relay

What is the difference between a contactor and a relay?

A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.

How do I calculate the correct contactor size for a motor?

Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.

Do you supply the coil voltage I need?

Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.

Are auxiliary contacts included?

Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.