MSQ Current Transformers The MSQ series of CT can be applied to test, control, display and record the running of the electrical equipment,…
The MSQ Current Transformer is part of the ELEHPD Current Transformer range. MSQ Current Transformers The MSQ series of CT can be applied to test, control, display and record the running of the electrical equipment, and to protect the equipment against the damage, in the AC circuit with the rated voltage &#118alue below 720V and the frequency of 50-60Hz. The product can be also applied to form a complete set of mine transformer The products comply with VDE 0414, BS7626 and IEC 44-1 standard. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
|
MSQ Current Transformers | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The MSQ series of CT can be applied to test, control, display and record the running of the electrical equipment, and to protect the equipment against the damage, in the AC circuit with the rated voltage &#118alue below 720V and the frequency of 50-60Hz. The product can be also applied to form a complete set of mine transformer Technical characteristics of current transformers: WITH BUSBAR
MOUNTING MSQ-30T Busbar dimensions (max): 30 X 20mm MSQ-30 Busbar dimensions (max): 30 X 20mm MSQ-40 Busbar dimensions (max): 40 X 10mm DIMENSIONS: Busbar dimensions (max): 60 X 20mm MSQ-85 Busbar dimensions (max): 82 X 30mm MSQ-100 Busbar dimensions (max): 100 X 10mm MSQ-125 Busbar dimensions (max): 126 X 60mm
|
For continuous industrial duty plan on 20-30 % headroom above the measured load. For loads with high inrush, such as motors or capacitive input, allow more and check the surge rating rather than only the average current.
Input ranges are model-specific and shown in the specification table. Where a wide-range input is available it is stated; otherwise send your mains voltage and we will match the model.
Typical protection covers short circuit, over-current, over-voltage and thermal shutdown. The exact set is listed per model in the specification table above.
Open-frame, enclosed and DIN-rail variants exist across this family. Send the model you are working from and we will confirm the equivalent mounting option.