Electrical Items › AC Contactor

LC1-D/Old AC Contactor

APPLICATION LC1-D/Old series AC contactor is suitable for suing in the circuits up to rated voltage 660V AC 50/60HZ, rated current up to 95…

  • Category: Electrical Items › AC Contactor
  • Model: 512
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this AC Contactor

About the LC1-D/Old AC Contactor

The LC1-D/Old AC Contactor is part of the ELEHPD AC Contactor range. APPLICATION LC1-D/Old series AC contactor is suitable for suing in the circuits up to rated voltage 660V AC 50/60HZ, rated current up to 95A, for making, breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contactor, mechanical interlocking contactor, and star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The contactor is produced according to IEC947-2, VDE0660 & BS5452. SPECIFICATION Type ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Typical applications

How to specify the right AC Contactor

  1. Match the rated current to the circuit design current, then check the cable ampacity
  2. Pick the trip curve to the load: B for resistive/lighting, C for general mixed loads, D for motors and transformers
  3. Confirm the breaking capacity meets the prospective short-circuit current at the point of installation
  4. Verify the pole configuration (1P, 1P+N, 2P, 3P, 3P+N, 4P) against the system earthing arrangement

Specifications


 
LC1-D/Old AC CONTACTOR

APPLICATION
 LC1-D/Old series AC contactor is suitable for suing in the circuits up to rated voltage 660V AC 50/60HZ, rated current up to 95A, for making, breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contactor, mechanical interlocking contactor, and star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The contactor is produced according to IEC947-2, VDE0660 & BS5452.

SPECIFICATION

Type

LC1-D09 LC1-D12 LC1-D18 LC1-D25 LC1-D32
Rated working current(A) AC3 9 12 18 25 32
AC4 3.5 5 7.7 8.5 12
AC3 capacity of phase 3 squirrel-cage motor AC3(KW) 220/230V 2.2 3 4 5.5 7.5
380/400V 4 5.5 7.5 11 15
415V 4 5.5 9 11 15
440V 4 5.5 9 11 15
500V 5.5 7.5 10 15 18.5
660/690V 5.5 7.5 10 15 18.5

Rated heat current (A)

20 20 32 40 50
Electrical life AC4×104 20 20-15 20-7 15-7 15-7
AC3×106 2 2 2 2 2

Mechanical life×106

20

20

20

20

20

Number of the contacts

3P+NO

3P+NC

Type

LC1-D40

LC1-D50

LC1-D65

LC1-D80

LC1-D95

Rated working current(A)

AC3

40

50

65

80

95

AC4

18.5

24

28

37

44

AC3 capacity of phase 3 squirrel-cage motor AC3(KW)

220/230V

11

15

18.5

22

25

380/400V

18.5

22

30

37

45

415V

22

25

37

45

45

440V

22

30

37

45

45

500V

22

30

37

55

55

660/690V

30

33

37

45

45

Rated heat current (A)

60

80

80

125

125

Electrical life

AC4×104

10-7

7

7-6

7-5

7-5

AC3×106

2

2

1.6

1.6

1.6

Mechanical life×106

20

20

20

20

20

Number of the contacts

3P+NO+NC


OUTLINE & MOUNTING SIZES
Outline & mouting sizes of LC1-115-330 contactors are shown as followings:
Type A B C b1 P Q S Q1 M H L φ Ga Ha
LC1-115 167 163 172 137 37 70 20 60 147 124 107 M6 80 110
LC1-150 167 171 172 137 40 70 20 57.5 150 124 107 M8
LC1-185 171 174 183 137 40 71 20 59.5 154 127 113.5 M8
LC1-225 171 197 183 137 48 71 25 51.5 172 127 113.5 M10
LC1-265 204 203 215 145 48 87 25 66.5 178 147 141 M10 96
LC1-330 213 206 220 145 48 91 25 74 181 181 145 M10

 

Frequently asked questions about the LC1-D/Old AC Contactor

What is the difference between an MCB and an MCCB?

An MCB (miniature circuit breaker) is a DIN-rail device for final circuits, typically rated up to 125 A with a fixed trip curve. An MCCB (moulded case circuit breaker) is a larger device for main and sub-main distribution, usually 16 A to 1600 A, with adjustable thermal and magnetic settings and a higher breaking capacity. Use an MCB for branch circuits and an MCCB where you need adjustability or higher fault ratings.

How do I choose between a Type B, C and D trip curve?

Type B trips between 3 and 5 times rated current and suits resistive loads such as lighting and heaters. Type C trips between 5 and 10 times and is the general-purpose choice for socket circuits and mixed loads. Type D trips between 10 and 20 times and is used for loads with high inrush, such as motors, transformers and large LED drivers.

What does 6 kA breaking capacity mean in practice?

It is the maximum prospective short-circuit current the device can safely interrupt. 6 kA covers most domestic and light commercial installations. Where the transformer is close and the fault level is higher, specify 10 kA devices so the breaker still clears the fault without damage.

Can these devices be supplied with your own brand?

Yes. OEM branding, buyer-specific labels, custom carton print and private-model numbering can be arranged on qualified order volumes.