40W Single switching power supply 12v 24v 5v Features: • Universal AC input / Full range • Protections:Short circuit/Over load • Cooling by…
The S series 12V 24V power supply S-40W is part of the ELEHPD S Series range. 40W Single switching power supply 12v 24v 5v Features: • Universal AC input / Full range • Protections:Short circuit/Over load • Cooling by free air convection • 100% full load burn-in test • Fixed switching frequency at 36KHz • 2 years warranty PARAMETER SHEET ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
40W Single switching power supply 12v 24v 5v
Features :
• Universal AC input / Full range
• Protections:Short circuit/Over load
• Cooling by free air convection
• 100% full load burn-in test
• Fixed switching frequency at 36KHz
• 2 years warranty
PARAMETER SHEET
| Model | S-40-5 | S-40-12 | S-40-15 | S-40-24 | |
| Output | DC Voltage | 5V | 12V | 15V | 24V |
| Rated Current | 8A | 3.5A | 2.8A | 1.8A | |
| Current Range | 0~8A | 0~3.5A | 0~2.8A | 0~1.8A | |
| Rated Power | 40W | 42W | 42W | 43W | |
| Ripple & Noise (max.) Note.2 | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
| Voltage Adj. Range | 4.75~5.5V | 10.8~13.2V | 13.5~16.5V | 21.6~26.4V | |
| Voltage Tolerance Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
| Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| Load Regulation | ±1.0% | ±0.5% | ±0.5% | ±0.5% | |
| Setup,Rise, Hold time | 300ms, 50ms, 60ms/230VAC 800ms, 50ms, 15ms/115VAC at full load | ||||
| Input | Voltage Range | 85 ~ 132VAC / 170 ~ 264VAC selected by switch 240 ~ 370VDC | |||
| Frequency Range | 47~63HZ | ||||
| Efficiency(Typ.) | 72%/115VAC | 76%/115VAC | 76%/115VAC | 78%/115VAC | |
| AC Current | 1.2A/115VAC 0.6A/230VAC | ||||
| Inrush Current (max.) | COLD START 30A/115VAC 60A/230VAC | ||||
| Leakage Current | <1mA / 240VAC | ||||
| Protection | Over Load | 105 ~ 150% rated output power | |||
| Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||
| Over Voltage | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.25 ~ 20.25 | 27.6 ~ 32.4V | |
| Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||
| Environment | Working Temperature | -10 ~ +60°c (Refer to output load derating curve) | |||
| Working Humidity | 20~90% RH Non-condensing | ||||
| Storage temp.& humidity | -20~+85°C, 10~95%RH | ||||
| Temp. coefficient | ±0.03%/°C (0~50°C) | ||||
| Vibration | 10 ~ 500Hz, 2G 10min./1 cycle,60min.each along X,Y,Z axes | ||||
| Safety & EMC (Note 4.) | Safety Standards | UL1012, UL1950, TUV EN60950 Approved | |||
| Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||
| EMI Conduction & Radiation | Compliance to EN55022 (CISPR22) Class B | ||||
| Harmonic Current | Compliance to EN61000-3-2,-3 | ||||
| EMS Immunity | Compliance to EN61000-4-2,3,4,5; ENV50204, EN55024, Light industry level, criteria A | ||||
| Others | MTBF | 314.1K hrs min. MIL-HDBK-217F (25°c ) | |||
| Dimension | 129*98*38mm (L*W*H) | ||||
| Packing | 0.41Kg; 30pcs/13.9Kg/0.86CUFT | ||||
| Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. | ||||
| 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||||
| 3. Tolerance : includes set up tolerance, line regulation and load regulation. | |||||
| 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets |
OVERALL DIMENSION
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.