Global Trade · Reliable Power Solutions E-mail: [email protected]
Electrical Items › Timer

TB-35 Timer Switch

TB-35 Timer Switch from the ELEHPD Timer range.

  • Category: Electrical Items › Timer
  • Model: 2697
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this Timer

About the TB-35 Timer Switch

The TB-35 Timer Switch is part of the ELEHPD Timer range. TB-35 Timer Switch from the ELEHPD Timer range. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Typical applications

How to specify the right Timer

  1. Size the contact rating for the inductive load, not just the resistive current (AC-3 duty for motors)
  2. Check the coil voltage and frequency available in the panel: 24 V DC, 110 V, 230 V or 400 V AC
  3. Confirm the auxiliary contact count needed for the control and indication circuit
  4. Match the enclosure rating to the environment (IP20 inside a panel, IP65 on the machine)

Specifications


                                                                                                                                                        

PRODUCT SPECIFICATIONS

CLASSIFCATION TIMER
MODEL TB-35
CONTACT CAPACITY AC220V 10A
FULL TIMING RANGE 24h
CONTACT RESISTANGE ≤50mΩ
INSULATION RESISTANCE ≥100mΩ
COIL VOLTAGE 100-240V AC
LIFE ELECTRICAL 107times
MECHANICAL 105times
OPERATING TEMPERATURE -40℃~+55℃
STO NAGE BATTERY with/without
SET UP TIMES 15 m per times    96 times
REMARKS --
 

Frequently asked questions about the TB-35 Timer Switch

What is the difference between a contactor and a relay?

A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.

How do I calculate the correct contactor size for a motor?

Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.

Do you supply the coil voltage I need?

Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.

Are auxiliary contacts included?

Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.

Related Timer models