Features: High efficiency, high reliability and low cost Switch input voltage range choice 100% full load and machine test Protection chara…
The Adjustable high walt Single Output Switching is part of the ELEHPD S Series range. Features: High efficiency, high reliability and low cost Switch input voltage range choice 100% full load and machine test Protection characteristics: short circuit/overload Air cooling ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
Full catalogue description: adjustable high walt Single Output Switching power supply AC to DC 110V or 220V 1000W
| Model | S-1000-12 | S-1000-15 | S-1000-24 | S-1000-48 | |
| Output | DC output Voltage | 12V | 15V | 24V | 48V |
| Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
| Rated Current | 80A | 67A | 40A | 20A | |
| Related Power | 1000w | 1000w | 1000w | 1000w | |
| Wave&Noise | 240mVp-p | 240mVp-p | 240mVp-p | 300mVp-p | |
| Adjustable range for DC Voltage | ±10% | ±10% | ±10% | ±10% | |
| Set up,rise,hold up time | 200ms 100ms 30ms | ||||
| Input | Voltage Range | 170-264VAC 47-63HZ | |||
| Input Current | 7A/230VAC | ||||
| Efficiency | 83% | 84% | 85% | 87% | |
| AC inrush current | Cold start current 50A /230VAC | ||||
| Leakage current | <3.5mA/240VAC | ||||
| Protection | Overload | Related output power 105-150% start overload protection | |||
| Protection type: cutoff output, recovery after restart power | |||||
| Over voltage | 13.8V-16.2V | 17.2V-20.2V | 27.6V-32.4V | 55V-64.8V | |
| Hiccup mode,recovers automatically after fault condition | |||||
| Environment | Working temp humidity | -10~+60°C 20%~90%RH | |||
| Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | ||||
| Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | |||
| I/P-FG:1.5KVAC 1min | |||||
| O/P-FG:0.5KVAC 1min | |||||
| Standard | Safety standard | Fit UL1012 | |||
| Refer | Design refer to GB4943,UL60950,EN60950 | ||||
| EMC standard | Design refer to GB9254,EN55022 Class A | ||||
| Size | size | 245X125X65mm | |||
| Package | 2kg, 4pcs/10kg |
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.