Ultra Thin EDR Series DIN Rail Switching Power from the ELEHPD EDR-Series range.
The Ultra Thin EDR Series DIN Rail Switching Power is part of the ELEHPD EDR-Series range. Ultra Thin EDR Series DIN Rail Switching Power from the ELEHPD EDR-Series range. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
Full catalogue description: Ultra Thin EDR Series 240W DIN Rail Switching Power Supply
| SPECIFICATIONS | ||
| OUTPUT | ||
| Model | EDR-240-24 | EDR-240-48 |
| DC Voltage | 24V | 48V |
| Rated Current | 10A | 5A |
| Current Range | 0-10A | 0-5A |
| Rated Power | 240W | 240W |
| Ripple & Noise | 150mVp-p | 360mVp-p |
| Voltage Adj. Range | 21-28V | 43-53V |
| Voltage Tolerance | ±1% | ±1% |
| Setup, Rise Time | 800ms,40ms/230VAC 800ms,40ms/115VAC at full load | |
| Hold Up Time | 24ms/230VAC 24ms/115VAC at full load | |
| Voltage Range | 176~264VAC 47~63Hz; 240~370VDC | |
| AC Current | 2.8A/115V 1.4A/230V | |
| Efficiency | 84% | 85% |
| Inrush Current | Cold start 27A/115V 45A/230V | |
| Leakage Current | <3.5mA/240VAC | |
| Over Load | 105%~150% | |
| Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||
| Over Voltage | 30-36V | 54-60V |
| Protection type: Shut down o/p voltage, re-power on to recover | ||
| Over Temp. | 100ºC±5ºC(TSW1) | |
| Protection type: Shut down o/p voltage, recovers automatically after temperature goes down | ||
| Working Temp., Humidity | -10ºC~+70ºC; 20%~90%RH | |
| Storage Temp., Humidity | -20ºC~+85ºC; 10%~95%RH | |
| Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | |
| Withstand Voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC | |
| Safety Standard | Design refer to UL508,UL60950-1, TUV EN60950-1 | |
| EMC Standard | EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2) | |
| Dimension | 63*125.2*115mm(L*W*H) | |
| Weight | 0.85Kg | |
| Packing | 20pcs/17.5Kg/1.2CUFT | |
| NOTE | ||
| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3 .Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5 . Derating may be needed under low input voltages. Please check the derating curve for more details. |
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.