EDR Single Output Switching Power Supply DIN from the ELEHPD EDR-Series range.
The EDR Single Output Switching Power Supply DIN is part of the ELEHPD EDR-Series range. EDR Single Output Switching Power Supply DIN from the ELEHPD EDR-Series range. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
Full catalogue description: EDR 120W Single Output Switching Power Supply DIN Rail SMPS
| MODEL | EDR-120-12 | EDR-120-24 | EDR-120-48 | |
OUTPUT | DC VOLTAGE | 12V | 24V | 48V |
| RATED CURRENT | 10A | 5A | 2.5A | |
| CURRENT RANGE | 0 ~ 10A | 0 ~ 5A | 0 ~ 2.5A | |
| RATED POWER | 120W | 120W | 120W | |
| RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 150mVp-p | |
| VOLTAGE ADJ. RANGE | 12 ~ 14V | 24 ~ 28V | 48 ~ 55V | |
| VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | |
| LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
| LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | |
| SETUP, RISE TIME | 1200ms, 60ms/230VAC 2500ms, 60ms/115VAC at full load | |||
| HOLD UP TIME (Typ.) | 16ms/230VAC 10ms/115VAC at full load | |||
INPUT | VOLTAGE RANGE Note.6 | 90 ~ 264VAC 127 ~ 370VDC | [DC input operation possible by connecting AC/L(+), AC/N(-)] | |
| FREQUENCY RANGE | 47 ~ 63Hz | |||
| EFFICIENCY (Typ.) | 85% | 87.5% | 88.5% | |
| AC CURRENT (Typ.) | 2.25A/115VAC 1.3A/230VAC | |||
| INRUSH CURRENT (Typ.) | 20A/115VAC 35A/230VAC | |||
| LEAKAGE CURRENT | <1mA / 240VAC | |||
PROTECTION | OVERLOAD | 105 ~ 130% rated output power | ||
| Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||
OVER VOLTAGE | 14 ~ 17V | 29 ~ 33V | 56 ~ 65V | |
| Protection type : Shut down o/p voltage, re-power on to recover | ||||
| OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |||
ENVIRONMENT | WORKING TEMP. | -20 ~ +60ºC (Refer to "Derating Curve") | ||
| WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||
| STORAGE TEMP., HUMIDITY | -40 ~ +85ºC, 10 ~ 95% RH | |||
| TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | |||
| VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | |||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | UL508, TUV EN62368-1, EAC TP TC 004, BSMI CNS14336-1 approved;(meet EN60204-1) | ||
| WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25ºC/ 70% RH | |||
| EMC EMISSION | Compliance to EN55032 (CISPR32) Class A, EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class A | |||
| EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020 | |||
OTHERS | MTBF | 474.6K hrs min. MIL-HDBK-217F (25ºC) | ||
| DIMENSION | 40*125.2*113.5mm (W*H*D) | |||
| PACKING | 0.6Kg; 20pcs/13Kg/1.16CUFT | |||
| NOTE | All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. Tolerance : includes set up tolerance, line regulation and load regulation. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. lnstallation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. ln case the adjacent device is a heat source, 15mm clearance is recommended. Derating may be needed under low input voltage. Please check the derating curve for more details. The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altitude higher than 2000m(6500ft}. |
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.