Global Trade · Reliable Power Solutions E-mail: [email protected]
Industrial Control › LRS Series

Slim Size Lrs DC Switching Power Supply for

Slim Size Lrs DC Switching Power Supply for from the ELEHPD LRS Series range.

  • Category: Industrial Control › LRS Series
  • Model: chance_568
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this LRS Series

About the Slim Size Lrs DC Switching Power Supply for

The Slim Size Lrs DC Switching Power Supply for is part of the ELEHPD LRS Series range. Slim Size Lrs DC Switching Power Supply for from the ELEHPD LRS Series range. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Full catalogue description: Slim Size Lrs 75W 12V 24V DC Switching Power Supply for LED Industrial Equipment Single Output

Typical applications

How to specify the right LRS Series

  1. Size the contact rating for the inductive load, not just the resistive current (AC-3 duty for motors)
  2. Check the coil voltage and frequency available in the panel: 24 V DC, 110 V, 230 V or 400 V AC
  3. Confirm the auxiliary contact count needed for the control and indication circuit
  4. Match the enclosure rating to the environment (IP20 inside a panel, IP65 on the machine)

Specifications

Slim Size Lrs 75W 12V 24V DC Switching Power Supply for LED Industrial Equipment Single Output
SPECIFICATION
OUTPUT
Model LRS-75-5 LRS-75-12 LRS-75-15 LRS-75-24 LRS-75-36 LRS-75-48
DC Voltage 5V 12V 15V 24V 36V 48V
Rated Current 14A 6A 5A 3.2A 2.1A 1.6A
Current Range 0~14A 0~6A 0~5A 0~3.2A 0~2.1A 0~1.6A
Rated Power 70W 72W 75W 76.8W 75.6W 76.8W
Ripple & Noise 100mVp-p 120mVp-p 120mVp-p 150mVp-p 200mVp-p 200mVp-p
Voltage Adj. Range 4.5 ~ 5.5V 10.2~ 13.8V 13.5~18V 21.6~28.8V 32.4~39.6V 43.2~52.8V
Voltage Tolerance ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Setup, Rise Time 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
Hold Up Time 60ms/230VAC 12ms/115VAC at full load
Voltage Range 85 ~ 264VAC 120 ~ 373VDC
Frequency Range 47 ~ 63Hz
Efficiency 86.5% 89% 89% 90% 91.5% 91.5%
AC Current 1.4A/115VAC 0.85A/230VAC
Inrush Current Cold start 50A/230VAC
Leakage Current <0.75mA / 240VAC
Over Load 110 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over Voltage 5.75~6.75V 13.8 ~ 16.2V 18.75~21.75V 28.8 ~ 33.6V 41.4~48.6V 55.2~ 64.8V
Protection type: shut down o/p voltage, re-power on to recover
Working Temp. -30 ~ +70ºC (Refer to "derating curve")
Working Humidity 20 ~ 90% RH non-condensing
Storage Temp., Humidity -40 ~ +85ºC, 10 ~ 95% RH
Temp. Coefficient ±0.03%/ºC (0 ~ 50ºC)
Vibration 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
Safety Standards UL60950-1, TUV EN60950-1, EN60335-1/-2-16, CCC GB4943 approved
Withstand Voltage I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH
EMC Emission Compliance to EN55022(CISPR22), GB9254 CLASS B, EN55014 EN 61000-3-2,-3
EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2), heavy industry level, criteria A
Dimension 99*82*30mm (L*W*H)
Weight 0.3Kg
Packing 45pcs/carton/14.5kg/0.77CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.

Frequently asked questions about the Slim Size Lrs DC Switching Power Supply for

What is the difference between a contactor and a relay?

A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.

How do I calculate the correct contactor size for a motor?

Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.

Do you supply the coil voltage I need?

Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.

Are auxiliary contacts included?

Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.

Related LRS Series models

Further reading