Lrs SMPS Variable DC Power Supply for from the ELEHPD LRS Series range.
The Lrs SMPS Variable DC Power Supply for is part of the ELEHPD LRS Series range. Lrs SMPS Variable DC Power Supply for from the ELEHPD LRS Series range. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
Full catalogue description: Lrs 100W SMPS Variable DC Power Supply for Industrial Equipment Supplies LED Switching Power Supply
| SPECIFICATION | |||||||
| OUTPUT | |||||||
| Model | LRS-100-3.3 | LRS-100-5 | LRS-100-12 | LRS-100-15 | LRS-100-24 | LRS-100-36 | LRS-100-48 |
| DC Voltage | 3.3V | 5V | 12V | 15V | 24V | 36V | 48V |
| Rated Current | 20A | 18A | 8.5A | 7A | 4.5A | 2.8A | 2.3A |
| Current Range | 0~20A | 0~18A | 0~8.5A | 0~7A | 0~4.5A | 0~2.8A | 0~2.3A |
| Rated Power | 66W | 90W | 102W | 105W | 108W | 100.8W | 110.4W |
| Ripple & Noise | 100mVp-p | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p |
| Voltage Adj. Range | 2.97~3.6V | 4.5 ~ 5.5V | 10.2~ 13.8V | 13.5~18V | 21.6~28.8V | 32.4~39.6V | 43.2~52.8V |
| Voltage Tolerance | ±3.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
| Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load Regulation | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Setup, Rise Time | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load | ||||||
| Hold Up Time | 55ms/230VAC 10ms/115VAC at full load | ||||||
| INPUT | |||||||
| Voltage Range | 85 ~ 264VAC 120 ~ 373VDC | ||||||
| Frequency Range | 47 ~ 63Hz | ||||||
| Efficiency | 84.50% | 86% | 88% | 88.50% | 90% | 90.50% | 91% |
| AC Current | 1.9A/115VAC 1.2A/230VAC | ||||||
| Inrush Current | Cold start 50A/230VAC | ||||||
| Leakage Current | <0.75mA / 240VAC | ||||||
| PROTECTION | |||||||
| Over Load | 110 ~ 150% rated output power | ||||||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||
| Over Voltage | 3.8~4.45V | 5.75~6.75V | 13.8 ~ 16.2V | 18.75~21.75V | 28.8 ~ 33.6V | 41.4~48.6V | 55.2~ 64.8V |
| Protection type: shut down o/p voltage, re-power on to recover | |||||||
| ENVIRONMENT | |||||||
| Working Temp. | -30 ~ +70ºC (Refer to "derating curve") | ||||||
| Working Humidity | 20 ~ 90% RH non-condensing | ||||||
| Storage Temp., Humidity | -40 ~ +85ºC, 10 ~ 95% RH | ||||||
| Temp. Coefficient | ±0.03%/ºC (0 ~ 50ºC) | ||||||
| Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
| SAFETY & EMC | |||||||
| Safety Standards | UL60950-1, TUV EN60950-1, EN60335-1/-2-16, CCC GB4943 approved | ||||||
| Withstand Voltage | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | ||||||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH | ||||||
| EMC Emission | Compliance to EN55022(CISPR22), GB9254 CLASS B, EN55014 EN 61000-3-2,-3 | ||||||
| EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2), heavy industry level, criteria A | ||||||
| OTHERS | |||||||
| Dimension | 129*97*30mm (L*W*H) | ||||||
| Weight | 0.34Kg | ||||||
| Packing | 40pcs/carton/14.6kg/0.92CUFT | ||||||
| NOTE |
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.