Global Trade · Reliable Power Solutions E-mail: [email protected]
Industrial Control › LRS Series

Lrs Series SMPS Variable DC Power Supply for

Lrs Series SMPS Variable DC Power Supply for from the ELEHPD LRS Series range.

  • Category: Industrial Control › LRS Series
  • Model: chance_564
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this LRS Series

About the Lrs Series SMPS Variable DC Power Supply for

The Lrs Series SMPS Variable DC Power Supply for is part of the ELEHPD LRS Series range. Lrs Series SMPS Variable DC Power Supply for from the ELEHPD LRS Series range. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Full catalogue description: Lrs Series 50W SMPS Variable DC Power Supply for Industrial Equipment Supplies LED CCTV

Typical applications

How to specify the right LRS Series

  1. Size the contact rating for the inductive load, not just the resistive current (AC-3 duty for motors)
  2. Check the coil voltage and frequency available in the panel: 24 V DC, 110 V, 230 V or 400 V AC
  3. Confirm the auxiliary contact count needed for the control and indication circuit
  4. Match the enclosure rating to the environment (IP20 inside a panel, IP65 on the machine)

Specifications

Lrs Series 50W SMPS Variable DC Power Supply for Industrial Equipment Supplies LED CCTV

Model LRS-50-12 LRS-50-15 LRS-50-24 LRS-50-36 LRS-50-48
DC Voltage 12V 15V 24V 36V 48V
Rated Current 4.2A 3.4A 2.2A 1.45A 1.1A
Current Range 0~4.2A 0~3.4A 0~2.2A 0~1.45A 0~1.1A
Rated Power 50.4W 51W 52.8W 52.2W 52.8W
Ripple and Noise 120mvp-p 120mvp-p 150mvp-p 200mvp-p 200mvp-p
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Setup, Rise time 1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full load
Hold up time 30ms/230VAC 12ms/115VAC at full load
Voltage Range 85 ~ 264VAC 120 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
Frequency Range 47~63HZ
Efficiency 86% 86% 88% 89% 90%
AC Current 0.95A/115VAC 0.56A/230VAC
Inrush Current COLD START 45A/230VAC
Leakage Current <0.75mA / 240VAC
Over Load 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Working Temp -20 ~ +70ºC (Refer to "Derating Curve")
Working Humidity 20 ~ 90% RH non-condensing
Storage temp,humidity -40 ~ +85ºC, 10 ~ 95% RH
Temp. Coefficient ±0.03%/ºC (0 ~ 50ºC)
Withstand Voltage I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
lsolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/ 70% RH
Demension 99*82*30mm (L*W*H)
Weight/Packing 0.23Kg

Frequently asked questions about the Lrs Series SMPS Variable DC Power Supply for

What is the difference between a contactor and a relay?

A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.

How do I calculate the correct contactor size for a motor?

Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.

Do you supply the coil voltage I need?

Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.

Are auxiliary contacts included?

Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.