Lrs Ultra Thin Switching Power Supply DC from the ELEHPD LRS Series range.
The Lrs Ultra Thin Switching Power Supply DC is part of the ELEHPD LRS Series range. Lrs Ultra Thin Switching Power Supply DC from the ELEHPD LRS Series range. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
Full catalogue description: Lrs Ultra Thin Switching Power Supply 350W 12V 24V 36V 48V DC Industrial SMPS
| SPECIFICATION | |||||||
| OUTPUT | |||||||
| Model | LRS-350-3.3 | LRS-350-5 | LRS-350-12 | LRS-350-15 | LRS-350-24 | LRS-350-36 | LRS-350-48 |
| DC Voltage | 3.3V | 5V | 12V | 15V | 24V | 36V | 48V |
| Rated Current | 60A | 60A | 29A | 23.2A | 14.6A | 9.7A | 7.3A |
| Current Range | 0~60A | 0~60A | 0~29A | 0~23.2A | 0~14.6A | 0~9.7A | 0~7.3A |
| Rated Power | 198W | 300W | 348W | 348W | 350.4W | 349.2W | 350.4W |
| Ripple & Noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p |
| Voltage Adj. Range | 2.97~3.6V | 4.5 ~ 5.5V | 10~ 13.8V | 13.5~18V | 21.6~28.8V | 32.4~39.6V | 43.2~52.8V |
| Voltage Tolerance | ±4.0% | ±3.0% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
| Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load Regulation | ±2.5% | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Setup, Rise Time | 1300ms, 50ms/230VAC 1300ms, 50ms/115VAC at full load | ||||||
| Hold Up Time | 16ms/230VAC 12ms/115VAC at full load | ||||||
| Voltage Range | 90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC (switch on 230VAC) | ||||||
| Frequency Range | 47 ~ 63Hz | ||||||
| Efficiency | 79.50% | 83.50% | 85% | 86% | 88% | 88.50% | 89% |
| AC Current | 6.8A/115VAC 3.4A/230VAC | ||||||
| Inrush Current | 60A/115VAC 60A/230VAC | ||||||
| Leakage Current | <2mA / 240VAC | ||||||
| Over Load | 110 ~ 140% rated output power | ||||||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||
| Over Voltage | 3.8~4.45V | 5.75~6.75V | 13.8 ~ 16.2V | 18~21V | 28.8 ~ 33.6V | 41.4~46.8V | 55.2~ 64.8V |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||
| Over temperature | Hiccup mode, recovers automatically after fault condition is removed | ||||||
| Working Temp. | -20 ~ +70ºC (Refer to "derating curve") | ||||||
| Working Humidity | 20 ~ 90% RH non-condensing | ||||||
| Storage Temp.,Humidity | -40 ~ +85ºC, 10 ~ 95% RH | ||||||
| Temp. Coefficient | ±0.03%/ºC (0 ~ 50ºC) | ||||||
| Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
| Safety Standards | UL60950-1 approved | ||||||
| Withstand Voltage | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH | ||||||
| Dimension | 215*115*30mm (L*W*H) | ||||||
| Weight | 0.76Kg | ||||||
| Packing | 20pcs/carton/16kg/0.78CUFT | ||||||
| NOTE | |||||||
| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.