Global Trade · Reliable Power Solutions E-mail: [email protected]
Industrial Control › LRS Series

AC to DC CCTV Single Output Switching Power

AC to DC CCTV Single Output Switching Power from the ELEHPD LRS Series range.

  • Category: Industrial Control › LRS Series
  • Model: chance_570
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this LRS Series

About the AC to DC CCTV Single Output Switching Power

The AC to DC CCTV Single Output Switching Power is part of the ELEHPD LRS Series range. AC to DC CCTV Single Output Switching Power from the ELEHPD LRS Series range. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Full catalogue description: AC to DC 200W 12V 17A CCTV Single Output Switching Power Supply

Typical applications

How to specify the right LRS Series

  1. Size the contact rating for the inductive load, not just the resistive current (AC-3 duty for motors)
  2. Check the coil voltage and frequency available in the panel: 24 V DC, 110 V, 230 V or 400 V AC
  3. Confirm the auxiliary contact count needed for the control and indication circuit
  4. Match the enclosure rating to the environment (IP20 inside a panel, IP65 on the machine)

Specifications

AC to DC 200W 12V 17A CCTV Single Output Switching Power Supply

SPECIFICATION
Model LRS-200-5 LRS-200-12 LRS-200-15 LRS-200-24 LRS-200-36 LRS-200-48
DC Voltage 5V 12V 15V 24V 36V 48V
Rated Current 40A 17A 14A 8.8A 5.9A 4.4A
Current Range 0~40A 0~17A 0~14A 0~8.8A 0~5.9A 0~4.4A
Rated Power 200W 204W 210W 211.2W 212.4W 211.2W
Ripple & Noise 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p
Voltage Adj. Range 4.5 ~ 5.5V 10.2~ 13.8V 13.5~18V 21.6~28.8V 32.4~39.6V 43.2~52.8V
Voltage Tolerance ±3.0% ±1.5% ±1.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
Setup, Rise Time 1300ms, 50ms/230VAC 1300ms, 50ms/115VAC at full load
Hold Up Time 16ms/230VAC 12ms/115VAC at full load
Voltage Range 90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC (switch on 230VAC)
Frequency Range 47 ~ 63Hz
Efficiency 87% 87.50% 88% 89.50% 89.50% 90%
AC Current 4A/115VAC 2.2A/230VAC
Inrush Current Cold start 60A/115VAC 60A/230VAC
Leakage Current <2mA / 240VAC
Over Load 110 ~ 140% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over Voltage 5.75~6.75V 13.8 ~ 16.2V 18~21V 28.8 ~ 33.6V 41.4~46.8V 55.2~ 64.8V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over temperature Hiccup mode, recovers automatically after fault condition is removed
Working Temp. -25 ~ +70ºC (Refer to "derating curve")
Working Humidity 20 ~ 90% RH non-condensing
Storage Temp., Humidity -40 ~ +85ºC, 10 ~ 95% RH
Temp. Coefficient ±0.03%/ºC (0 ~ 50ºC)
Vibration 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
Safety Standards UL60950-1 approved
Dimension 215*115*30mm (L*W*H)
Weight 0.68Kg
Packing 15pcs/carton/10.9kg/0.78CUFT
warranty 2 years

Frequently asked questions about the AC to DC CCTV Single Output Switching Power

What is the difference between a contactor and a relay?

A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.

How do I calculate the correct contactor size for a motor?

Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.

Do you supply the coil voltage I need?

Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.

Are auxiliary contacts included?

Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.