AC to DC CCTV Single Output Switching Power from the ELEHPD LRS Series range.
The AC to DC CCTV Single Output Switching Power is part of the ELEHPD LRS Series range. AC to DC CCTV Single Output Switching Power from the ELEHPD LRS Series range. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
Full catalogue description: AC to DC 200W 12V 17A CCTV Single Output Switching Power Supply
| SPECIFICATION | ||||||
| Model | LRS-200-5 | LRS-200-12 | LRS-200-15 | LRS-200-24 | LRS-200-36 | LRS-200-48 |
| DC Voltage | 5V | 12V | 15V | 24V | 36V | 48V |
| Rated Current | 40A | 17A | 14A | 8.8A | 5.9A | 4.4A |
| Current Range | 0~40A | 0~17A | 0~14A | 0~8.8A | 0~5.9A | 0~4.4A |
| Rated Power | 200W | 204W | 210W | 211.2W | 212.4W | 211.2W |
| Ripple & Noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p |
| Voltage Adj. Range | 4.5 ~ 5.5V | 10.2~ 13.8V | 13.5~18V | 21.6~28.8V | 32.4~39.6V | 43.2~52.8V |
| Voltage Tolerance | ±3.0% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
| Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load Regulation | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Setup, Rise Time | 1300ms, 50ms/230VAC 1300ms, 50ms/115VAC at full load | |||||
| Hold Up Time | 16ms/230VAC 12ms/115VAC at full load | |||||
| Voltage Range | 90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC (switch on 230VAC) | |||||
| Frequency Range | 47 ~ 63Hz | |||||
| Efficiency | 87% | 87.50% | 88% | 89.50% | 89.50% | 90% |
| AC Current | 4A/115VAC 2.2A/230VAC | |||||
| Inrush Current | Cold start 60A/115VAC 60A/230VAC | |||||
| Leakage Current | <2mA / 240VAC | |||||
| Over Load | 110 ~ 140% rated output power | |||||
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||
| Over Voltage | 5.75~6.75V | 13.8 ~ 16.2V | 18~21V | 28.8 ~ 33.6V | 41.4~46.8V | 55.2~ 64.8V |
| Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||
| Over temperature | Hiccup mode, recovers automatically after fault condition is removed | |||||
| Working Temp. | -25 ~ +70ºC (Refer to "derating curve") | |||||
| Working Humidity | 20 ~ 90% RH non-condensing | |||||
| Storage Temp., Humidity | -40 ~ +85ºC, 10 ~ 95% RH | |||||
| Temp. Coefficient | ±0.03%/ºC (0 ~ 50ºC) | |||||
| Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||
| Safety Standards | UL60950-1 approved | |||||
| Dimension | 215*115*30mm (L*W*H) | |||||
| Weight | 0.68Kg | |||||
| Packing | 15pcs/carton/10.9kg/0.78CUFT | |||||
| warranty | 2 years |
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.