NES SERIES POWER SUPPLY NES-75W

NES-75W HIGH EFFICIENCY SWITCHING POWER SUPPLY 75W NES-75W Features: • Universal AC input/Full range • Protections: Short circuit / Overloa…

  • Category: Industrial Control › NES Series
  • Model: chance_120
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this NES Series

About the NES SERIES POWER SUPPLY NES-75W

The NES SERIES POWER SUPPLY NES-75W is part of the ELEHPD NES Series range. NES-75W HIGH EFFICIENCY SWITCHING POWER SUPPLY 75W NES-75W Features: • Universal AC input/Full range • Protections: Short circuit / Overload / Over voltage • Cooling by free air convection • 100% full load burn-in test • 2 years warranty ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Typical applications

How to specify the right NES Series

  1. Size the contact rating for the inductive load, not just the resistive current (AC-3 duty for motors)
  2. Check the coil voltage and frequency available in the panel: 24 V DC, 110 V, 230 V or 400 V AC
  3. Confirm the auxiliary contact count needed for the control and indication circuit
  4. Match the enclosure rating to the environment (IP20 inside a panel, IP65 on the machine)

Specifications


NES-75W HIGH EFFICIENCY SWITCHING POWER SUPPLY 75W NES-75W

Features :

•Universal AC input/Full range

•Protections: Short circuit / Overload / Over voltage

•Cooling by free air convection

•100% full load burn-in test

•2 years warranty


MODEL

NES-75-5

NES-75-12

NES-75-15

NES-75-24

NES-75-48

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

48V

RATED CURRENT

14A

6.2A

5A

3.2A

1.6A

CURRENT RANGE

0-14A

0 ~ 6.2A

0-5A

0-3.2A

0-1.6A

RATED POWER

70W

74.4W

75W

76.8W

76.8W

RIPPLE & NOISE (max.) Note.2

80mVp-p

120mVp-p

150mVp-p

200mVp-p

240mVp-p

VOLTAGE ADJ. RANGE

4.75 - 5.5V

10.8-13.2V

13.5-16.5V

21.6-26.4V

43.2 - 52.8V

VOLTAGE TOLERANCE Note.3

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION Note.4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION Note.5

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load

HOLD UP TIME (Typ.)

50ms/230VAC 10ms/115VAC at full load

INPUT

VOLTAGE RANGE

85 ~ 264VAC 120-370VDC

FREQUENCY RANGE

47 - 63Hz

EFFICIENCY (Typ.)

77%

82%

83%

86%

87%

AC CURRENT (Typ.)

1.5A/115VAC 0.9 A/230VAC

INRUSH CURRENT (Typ.)

COLD START 45A

LEAKAGE CURRENT

<2mA/240VAC

PROTECTION

OVERLOAD

105 ~135%

110 ~ 150% rated output power

Protection type: Hiccup mode, recovers automatically after fault condition is removed

OVERVOLTAGE

5.75 ~ 6.75V

13.8-16.2V

17.25-20.25

27.6 - 32.4V

55.2 - 64.8V

Protection type: Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.

-20 ~ +60°C (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85°C, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/°C (0 ~ 45°C)

VIBRATION

10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes

SAFETY &

EMC

(Note 7)

SAFETY STANDARDS Note.6

UL60950-1, CB(IEC60950-1),CCC GB4943.1:2011 approved

WITHSTAND VOLTAGE

l/P-0/P:1.5KVAC l/P-FG:1.5KVAC 0/P-FG:0.5KVAC

ISOLATION RESISTANCE

l/P-O/P, l/P-FG, 0/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH

EMC EMISSION

Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteria A

OTHERS

MTBF

378.2K hrs min. MIL-HDBK-217F (25°C)

DIMENSION

159*97*38mm (L*W*H)

PACKING

0.52Kg; 30pcs/16.6Kg/0.97CUFT


Frequently asked questions about the NES SERIES POWER SUPPLY NES-75W

What is the difference between a contactor and a relay?

A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.

How do I calculate the correct contactor size for a motor?

Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.

Do you supply the coil voltage I need?

Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.

Are auxiliary contacts included?

Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.