NES-350W HIGH EFFICIENCY SWITCHING POWER SUPPLY 350W Features: •Protections: Short circuit / Overload / Over voltage/ Over temperature •For…
The NES SERIES POWER SUPPLY NES-350W is part of the ELEHPD NES Series range. NES-350W HIGH EFFICIENCY SWITCHING POWER SUPPLY 350W Features: •Protections: Short circuit / Overload / Over voltage/ Over temperature •Forced air cooling by built-in DC fan •Withstand 300vac surge input for 5 second •Built-in cooling Fan ON-OFF control •Built-in constant current limiting circuit •100% full load burn-in test •LED indicator for power on •Fixed switching frequency at 90KHz •Low cost,high reliability • ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
•Protections: Short circuit / Overload / Over voltage/ Over temperature
•Forced air cooling by built-in DC fan
•Withstand 300vac surge input for 5 second
•Built-in cooling Fan ON-OFF control
•Built-in constant current limiting circuit
•100% full load burn-in test
•LED indicator for power on
•Fixed switching frequency at 90KHz
•Low cost,high reliability
•2 years warranty
| MODEL | NES-350-5 | NES-350-12 | NES-350-15 | NES-350-24 | NES-350-48 | |
| OUTPUT | DC voltage | 5V | 12V | 15V | 24V | 48V |
| Voltage tolerance | ±2% | ±1% | ±1% | ±1% | ±1% | |
| Rated current | 60A | 29A | 23.3A | 14.6A | 7.3A | |
| Current range | 0~60A | 0~29A | 0~23.3A | 0~14.6A | 0~7.3A | |
| Rated power | 300W | 348W | 349.5W | 350.4W | 350.4W | |
| Ripple&noise | 150mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 240mvp-p | |
| DC voltage ADJ.range | -9%~+10% | ±10% | ±10% | ±10% | ±10% | |
| INPUT | Voltage range | 90~132VAC/180~264VAC(selected by switch),255~373VDC | ||||
| frequency | 47~63HZ | |||||
| AC current | 7A/115VAC,4A/230VAC | |||||
| efficiency | 80% | 84% | 84% | 86% | 87% | |
| Inrush current | Cold start current 40A/115VAC,60A/230VAC | |||||
| Leakage current | < 3.5mA/240VAC | |||||
| PROTECTION | overload | Rated output power 105%~135% start over load protection | ||||
| Protection type:hiccup mode,auto-recovery after fault condition is removed | ||||||
| Over voltage | 6.8~8.2V | 15.6~17.8V | 18.6~20.8V | 30.6~33.2V | 54.8~56.6V | |
| Protection type:hiccup mode,auto-recovery after fault condition is removed | ||||||
| Over temperature | ≥50ºC fan on,≤45ºCfan off,≥95ºC±5ºC start over temperature protection | |||||
| Protection mode:cutoff output,auto-recovery after temperature become normal | ||||||
| ENVIROMENT | Working temp,humidity | -20ºC~+60ºC,20%~90%RH | ||||
| Storagetemp,humidity | -40ºC~+85ºC,10%~95%RH non-condensing | |||||
| Withstand vibration | 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes | |||||
| SAFETY STANDARD& EMC | Withstand voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
| Isolated resistance | I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC | |||||
| Safety standard | DESIGN REFER TO UL1012 | |||||
| EMC standard | EN55022,CLASSA | |||||
| OTHERS | Dimension | 215*115*50mm (L*W*H) | ||||
| Weight/packing | 1.0kg/24pcs/25kg/0.049 m³/1.72CUFT | |||||
| NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.