Global Trade · Reliable Power Solutions E-mail: [email protected]
Industrial Control › NES Series

NES SERIES POWER SUPPLY NES-350W

NES-350W HIGH EFFICIENCY SWITCHING POWER SUPPLY 350W Features: •Protections: Short circuit / Overload / Over voltage/ Over temperature •For…

  • Category: Industrial Control › NES Series
  • Model: chance_185
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this NES Series

About the NES SERIES POWER SUPPLY NES-350W

The NES SERIES POWER SUPPLY NES-350W is part of the ELEHPD NES Series range. NES-350W HIGH EFFICIENCY SWITCHING POWER SUPPLY 350W Features: •Protections: Short circuit / Overload / Over voltage/ Over temperature •Forced air cooling by built-in DC fan •Withstand 300vac surge input for 5 second •Built-in cooling Fan ON-OFF control •Built-in constant current limiting circuit •100% full load burn-in test •LED indicator for power on •Fixed switching frequency at 90KHz •Low cost,high reliability • ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Typical applications

How to specify the right NES Series

  1. Size the contact rating for the inductive load, not just the resistive current (AC-3 duty for motors)
  2. Check the coil voltage and frequency available in the panel: 24 V DC, 110 V, 230 V or 400 V AC
  3. Confirm the auxiliary contact count needed for the control and indication circuit
  4. Match the enclosure rating to the environment (IP20 inside a panel, IP65 on the machine)

Specifications


NES-350W HIGH EFFICIENCY SWITCHING POWER SUPPLY 350W
Features :

•Protections: Short circuit / Overload / Over voltage/ Over temperature

•Forced air cooling by built-in DC fan

•Withstand 300vac surge input for 5 second

•Built-in cooling Fan ON-OFF control

•Built-in constant current limiting circuit

•100% full load burn-in test

•LED indicator for power on

•Fixed switching frequency at 90KHz

•Low cost,high reliability

•2 years warranty


MODEL NES-350-5 NES-350-12 NES-350-15 NES-350-24 NES-350-48

OUTPUT
DC voltage 5V 12V 15V 24V 48V
Voltage tolerance ±2% ±1% ±1% ±1% ±1%
Rated current 60A 29A 23.3A 14.6A 7.3A
Current range 0~60A 0~29A 0~23.3A 0~14.6A 0~7.3A
Rated power 300W 348W 349.5W 350.4W 350.4W
Ripple&noise 150mvp-p 150mvp-p 150mvp-p 150mvp-p 240mvp-p
DC voltage ADJ.range -9%~+10% ±10% ±10% ±10% ±10%

INPUT
Voltage range 90~132VAC/180~264VAC(selected by switch),255~373VDC
frequency 47~63HZ
AC current 7A/115VAC,4A/230VAC
efficiency 80% 84% 84% 86% 87%
Inrush current Cold start current 40A/115VAC,60A/230VAC
Leakage current < 3.5mA/240VAC

PROTECTION
overload Rated output power 105%~135% start over load protection
Protection type:hiccup mode,auto-recovery after fault condition is removed
Over voltage 6.8~8.2V 15.6~17.8V 18.6~20.8V 30.6~33.2V 54.8~56.6V
Protection type:hiccup mode,auto-recovery after fault condition is removed
Over temperature ≥50ºC fan on,≤45ºCfan off,≥95ºC±5ºC start over temperature protection
Protection mode:cutoff output,auto-recovery after temperature become normal
ENVIROMENT Working temp,humidity -20ºC~+60ºC,20%~90%RH
Storagetemp,humidity -40ºC~+85ºC,10%~95%RH non-condensing
Withstand vibration 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes
SAFETY STANDARD&
EMC
Withstand voltage I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolated resistance I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC
Safety standard DESIGN REFER TO UL1012
EMC standard EN55022,CLASSA
OTHERS Dimension 215*115*50mm (L*W*H)
Weight/packing 1.0kg/24pcs/25kg/0.049 m³/1.72CUFT
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.


Frequently asked questions about the NES SERIES POWER SUPPLY NES-350W

What is the difference between a contactor and a relay?

A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.

How do I calculate the correct contactor size for a motor?

Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.

Do you supply the coil voltage I need?

Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.

Are auxiliary contacts included?

Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.

Related NES Series models