Global Trade · Reliable Power Solutions E-mail: [email protected]
Industrial Control › NES Series

NES SERIES POWER SUPPLY NES-200W NES-200W HIGH

NES-200W HIGH EFFICIENCY SWITCHING POWER SUPPLY 200W Features: • AC input range selectable by switch • Protections: Short circuit / Overloa…

  • Category: Industrial Control › NES Series
  • Model: chance_283
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this NES Series

About the NES SERIES POWER SUPPLY NES-200W NES-200W HIGH

The NES SERIES POWER SUPPLY NES-200W NES-200W HIGH is part of the ELEHPD NES Series range. NES-200W HIGH EFFICIENCY SWITCHING POWER SUPPLY 200W Features: • AC input range selectable by switch • Protections: Short circuit / Overload / Over voltage/ Over temperature • Cooling by free air convection • Withstand 300vac surge input for 5 second • Built-in constant current limiting circuit • 100% full load burn-in test • LED indicator for power on • Fixed switching frequency at 90KHz • Low cost,high reliability ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Full catalogue description: NES SERIES POWER SUPPLY NES-200W NES-200W HIGH EFFICIENCY SWITCHING POWER SUPPLY 200W

Typical applications

How to specify the right NES Series

  1. Size the contact rating for the inductive load, not just the resistive current (AC-3 duty for motors)
  2. Check the coil voltage and frequency available in the panel: 24 V DC, 110 V, 230 V or 400 V AC
  3. Confirm the auxiliary contact count needed for the control and indication circuit
  4. Match the enclosure rating to the environment (IP20 inside a panel, IP65 on the machine)

Specifications

NES-200W HIGH EFFICIENCY SWITCHING POWER SUPPLY 200W

Features :

•AC input range selectable by switch

•Protections: Short circuit / Overload / Over voltage/

Over temperature

•Cooling by free air convection

•Withstand 300vac surge input for 5 second

•Built-in constant current limiting circuit

•100% full load burn-in test

•LED indicator for power on

•Fixed switching frequency at 90KHz

•Low cost,high reliability

•2 years warranty


Details:

MODEL

NES-200-5

NES-200-7.5

NES-200-9

N ES-200-12

NES-200-15

NES-200-24

NES-200-48

OUTPUT

DC VOLTAGE

5V

7.5V

9V

12V

15V

24V

48V

RATED CURRENT

40A

27A

11.2A

17A

14A

8.8A

4.4A

CURRENT RANGE

0 ~ 40A

0 ~ 27A

0 ~ 11.2A

0 ~ 17A

0 ~ 14A

0 ~ 8.8A

0 ~ 4.4A

RATED POWER

200W

200W

200W

200W

200W

200W

200W

RIPPLE & NOISE (max.) Note.2

80mVp-p

120mVp-p

120mVp-p

120mVp-p

120mVp-p

120mVp-p

150mVp-p

VOLTAGE ADJ. RANGE

4.75 ~ 5.5V

7.13 ~ 8.3V

8.55 ~ 9.9V

11.4 ~ 13.2V

14.25 ~ 16.5V

22.8 ~ 26.4V

45.6 ~ 52.8V

VOLTAGE TOLERANCE Note.3

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION Note.4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION Note.5

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

500ms, 20ms/230VAC 500ms, 20ms/115VAC at full load

HOLD UP TIME (Typ.)

30ms/230VAC 25ms/115VAC at full load

INPUT

VOLTAGE RANGE

85 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC

FREQUENCY RANGE

47 ~63Hz

EFFICIENCY(Typ.)

80%

81%

81%

83%

84%

86%

86%

AC CURRENT (Typ.)

2A/115VAC 1.2A/230VAC

INRUSH CURRENT (Typ.)

COLD START 36A

LEAKAGE CURRENT

<2mA/ 240VAC

PROTECTION

OVERLOAD

105 ~ 150% rated output power

Protection type : Constant current limiting, recovers automatically after fault condition is removed

OVER VOLTAGE

5.75 ~6.75V

8.6 ~ 10.1V

10.4 ~ 12.2V

13.8 ~ 16.2V

17.25 ~ 20.25V

27.6 ~ 32.4V

55.2 ~ 64.8V

Protection type : Shut down O/P voltage, recovers automatically after temperature goes down

ENVIRONMENT

WORKING TEMP.

-20 ~ +60”C (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85°C, 10 ~95% RH

TEMP. COEFFICIENT

±0.03%/°C (0 ~ 50°C)

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, period for60min. each along X, Y, Z axes

SAFETY &

EMC

(Note 6)

SAFETY STANDARDS

UL60950-1, CB(IEC60950-1),CCC GB4943 approved

WITHSTAND VOLTAGE

I/P-O/P:1.5KVAC I/PFG:1.5KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH

EMC EMISSION

Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteriaA

OTHERS

MTBF

271.9K hrs min. MIL-HDBK-217F (25°C)

DIMENSION

215*115*50mm (L*W*H)

PACKING

0.93Kg; 12pcs/12Kg/0.92CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a0.1uf& 47uf parallel capacitor.

3.Tolerance : includes set up tolerance, line regulation and load regulation.

4.Please connect positive pole of input voltage with mark “N” of terminal block, connect negative pole of input voltage with mark “L” of terminal block, using DC voltage for input voltage.


Frequently asked questions about the NES SERIES POWER SUPPLY NES-200W NES-200W HIGH

What is the difference between a contactor and a relay?

A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.

How do I calculate the correct contactor size for a motor?

Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.

Do you supply the coil voltage I need?

Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.

Are auxiliary contacts included?

Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.

Related NES Series models