Ⅰ. Main Technical Indexes 1.Service Conditions:Altitude:under 2000m Ambient temperature:-25℃~50℃ Relative humidity:≤90% at 25℃;≤50% at 40℃…
The MSMJ Metallized Pulse Capacitor is part of the ELEHPD Capacitor range. Ⅰ. Main Technical Indexes 1.Service Conditions:Altitude:under 2000m Ambient temperature:-25℃~50℃ Relative humidity:≤90% at 25℃;≤50% at 40℃ Declining degree of installation:≤5℃ 2.Rated Voltage:400V, 50Hz 3.Rated Output:9, 15, 18, 24, 30, 36, 48, 60, 80, 96, 120kvar(Asfor corre sponding transformer capacity for compensation, see table 1) 4.Rang of Working Voltage:0.85~1.10 times rated voltage 5.Max.permissible current:1.3 times rated current. 6.Number of Circuits Controlled:3 channels, 4 channels, 8 channels. 7.Switching Time:0~90s per time, continual digit type and adjustable. It has been set at 30s per time in factory. 8.Working Way:Automatic and continual operation. The capacitor applies the switching way of constant volume cycle:First throw in and first throw out, later throw in and later throw out, which can prolong the service life of the capacitor. 9.Cos &#118alue retains above 0.95 when load changes within 5~100%. 10.The installation is used indoors and its shell is designed wall build-up type. 11.Accord with JB/T7113-1993 Low-Voltage shunt Capacitor Installation. Ⅱ. Application Discharge in ultra short moment can produce strong pulse current.It can be widely used in new technologies like sunge voltage generator,surge curtent generator,magnetizer,plasma processing,laser,ets,The products meet JB/T8168-1999 Pulse Capacitor and DC Capactior Standard. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
| MSMJ type Metallized Pulse Capacitor |
For continuous industrial duty plan on 20-30 % headroom above the measured load. For loads with high inrush, such as motors or capacitive input, allow more and check the surge rating rather than only the average current.
Input ranges are model-specific and shown in the specification table. Where a wide-range input is available it is stated; otherwise send your mains voltage and we will match the model.
Typical protection covers short circuit, over-current, over-voltage and thermal shutdown. The exact set is listed per model in the specification table above.
Open-frame, enclosed and DIN-rail variants exist across this family. Send the model you are working from and we will confirm the equivalent mounting option.