Hdr-100 DIN Rail Single Output Power Supply DC from the ELEHPD HDR-Series range.
The Hdr-100 DIN Rail Single Output Power Supply DC is part of the ELEHPD HDR-Series range. Hdr-100 DIN Rail Single Output Power Supply DC from the ELEHPD HDR-Series range. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
Full catalogue description: Hdr-100 DIN Rail Single Output Power Supply 100W 12V 24V DC for Industrial Control System
| MODEL | HDR-100-12 | HDR-100-15 | HDR-100-24 | HDR-100-48 | |
| | DC Voltage | 12v | 15V | 24v | 48v |
| Rated Current | 7.5A | 6.5A | 4.2A | 2.1A | |
| Current range | 0~7.5A | 0~6.5A | 0~4.2A | 0~2.1A | |
| Rated power | 90w | 97.5w | 100.8w | 100.8W | |
| Ripple&noise(max.) | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | |
| Voltage ADJ. range | 12~13.8V | 13.5~18V | 21.6~29V | 43.2~55.2V | |
| Voltage tolerance | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
| Line regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
| Load regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
| Setup,Rise,Time | 500ms, 60ms/230VAC 500ms, 60ms/115VAC(full load) | ||||
| Hold up time | 30ms/230VAC 12ms/115VAC(full load) | ||||
| INPUT | Voltage range | 85~264VAC(277VACusable ) 120~370VDC(390VDCusable ) | |||
| Voltage range | 50~60Hz | ||||
| Efficiency | 88% | 89% | 90% | 90% | |
| AC current | 3A/115VAC 1.6A/230VAC | ||||
| Inrush current | Cold start: 35A/115VAC 70A/230VAC | ||||
| | Over load | 105~150% rated output power | |||
| | Protected mode: constant current mode, can be automatically restored after the load abnormal condition is removed | ||||
| Over voltage | 14.2~16.2V | 18.8~22.5V | 30~36V | 56.5~64.8V | |
| | Protective mode; Close the output and restart to restore | ||||
| | Working TEMP | -30~+70ºC | |||
| Working humidity | 20~90% RH,non-condensing | ||||
| Storage TEMP humidity | -40~+85ºC,10-95%RH,non-condensing | ||||
| TEMP.coefficient | ±0.03%ºC(0~50ºC) | ||||
| Vibration | 10~500Hz,2G 10min./1cycle,60min.each along X,Y,Z axes Install conform to IEC60068-2-6 | ||||
| Operating altitude | 2000m | ||||
| Over voltage class | ;According to EN61558 EN50178 EN60664-1, EN62477-1;The altitude can be as high as 2,000 meters |
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.