MDR 10W DIN RAIL SMPS PSU SWITCHING POWER SUPPLY Features 10W dinrail switching power supply Universal AC input/full range Protections: Sho…

  • Category: Industrial Control › MDR-Series
  • Model: chance_328
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this MDR-Series

About the Din rail switching power supply PSU SMPS MDR

The Din rail switching power supply PSU SMPS MDR is part of the ELEHPD MDR-Series range. MDR 10W DIN RAIL SMPS PSU SWITCHING POWER SUPPLY Features 10W dinrail switching power supply Universal AC input/full range Protections: Short circuit/over load/over voltage Cooling by free air convection Can be installed on DIN-Rail: TS-35/7.5 or TS-35/15 Built in DC OK active signal LED indicator for power on No load power consumption<0.75W 100% full load burn-in test 1 year warranty ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Full catalogue description: Din rail switching power supply PSU SMPS MDR 10W 12V 24V 5V

Typical applications

How to specify the right MDR-Series

  1. Size the contact rating for the inductive load, not just the resistive current (AC-3 duty for motors)
  2. Check the coil voltage and frequency available in the panel: 24 V DC, 110 V, 230 V or 400 V AC
  3. Confirm the auxiliary contact count needed for the control and indication circuit
  4. Match the enclosure rating to the environment (IP20 inside a panel, IP65 on the machine)

Specifications


MDR 10W DIN RAIL SMPS PSU SWITCHING POWER SUPPLY

Features

10W dinrail switching power supply
Universal AC input/full range
Protections: Short circuit/over load/over voltage
Cooling by free air convection
Can be installed on DIN-Rail: TS-35/7.5 or TS-35/15
Built in DC OK active signal
LED indicator for power on
No load power consumption<0.75W
100% full load burn-in test
1 year warranty
Model MDR-10-5 MDR-10-12 MDR-10-15 MDR-10-24
Output DC output Voltage 5V 12V 15V 24V
Voltage tolerance ±1.0% ±1.0% ±1.0% ±1.0%
Rated Current 2A 0.84A 0.67A 0.42A
Related Power 10w 10w 10w 10w
Wave&Noise 80mVp-p 120mVp-p 120mVp-p 150mVp-p
Set up,rise time 800ms 30ms/230VAC 1000ms,30ms/115VAC at full load
hold up time 120ms/230VAC 25ms/115VAC at full load
Input Voltage Range 85 ~ 264VAC 47-63HZ 120-370VDC
Input Current 0.33A/115VAC 0.21A/230VAC
Efficiency 77% 81% 81%% 84%
AC inrush current Cold start current 35A/115V 70A/230VAC
Leakage current <1mA/240VAC
Protection Overload Above 105% rated output power
hiccup mode, recovery automatically after fault condistion is removed
Over voltage 5.75V-6.75V 13.8V-16.2V 17.25-20.25V 27.6-32.4V
Shut down o/p voltage, re-power on to recover
Function DC OK active single 3.75-6V/50mA 9-13.5V/40mA 11.5-16.5V/40mA 18-27V/20mA
Environment Working temp humidity -20~+70°C 20%~90%RH
Stor temp, humidity -20~+85°C 20%~90%RH Non-condensing
Safety safety standards UL508,TUV EN60950-1 approved
Withstand voltage I/P-O/P:3KVAC I/P-FG:2KVA O/P-FG:0.5KVA
Isolation resistance I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25 /70%RH
EMC emission Compliance to EN55011,EN55022,EN61204-3 class B,EN61000-3-2,-3
Size size L22.5*W90*H100mm
Package 0.17kg,72pcs/14kg
Note:1.All parameters not specially mentioned are measured at 230VAC input, related load and 25 f ambient temperature.2.Wave&noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.3.Tolerance: includes set up tolerance, line regulation and load regulation.



Frequently asked questions about the Din rail switching power supply PSU SMPS MDR

What is the difference between a contactor and a relay?

A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.

How do I calculate the correct contactor size for a motor?

Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.

Do you supply the coil voltage I need?

Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.

Are auxiliary contacts included?

Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.

Related MDR-Series models

Further reading