BY30 Surge Arrestor

BY30 Surge protective device BY30-65/2 BY30-65/3 Specification Type Pole No. Uc (V) In (kA) Imax (kA) Up (kV) BY30-8/1-275 1 275 2 8 ≤ 1.2…

  • Category: Electrical Items › Surge Arrester
  • Model: 1733
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this Surge Arrester

About the BY30 Surge Arrestor

The BY30 Surge Arrestor is part of the ELEHPD Surge Arrester range. BY30 Surge protective device BY30-65/2 BY30-65/3 Specification Type Pole No. Uc (V) In (kA) Imax (kA) Up (kV) BY30-8/1-275 1 275 2 8 ≤ 1.2 BY30-15/1-275 1 275 5 15 ≤ 1.2 BY30-40/1-275 1 275 15 40 ≤ 1.2 BY30-65/1-275 1 275 20 65 ≤ 1.5 BY30-8/1-440 1 440 2 8 ≤ 1.8 BY30-15/1-440 1 440 5 15 ≤ 1.8 BY30-40/1-440 1 440 15 40 ≤ 1.8 BY30-65/1-440 1 440 20 65 ≤ 2.0 BY30-8/2-275 2 275 2 8 ≤ 1.2 BY3 ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Typical applications

How to specify the right Surge Arrester

  1. Match the rated current to the circuit design current, then check the cable ampacity
  2. Pick the trip curve to the load: B for resistive/lighting, C for general mixed loads, D for motors and transformers
  3. Confirm the breaking capacity meets the prospective short-circuit current at the point of installation
  4. Verify the pole configuration (1P, 1P+N, 2P, 3P, 3P+N, 4P) against the system earthing arrangement

Specifications


BY30 Surge protective device

BY30-65/2 BY30-65/3
Specification
Type
Pole No.
Uc (V)
In (kA)
Imax (kA)
Up (kV)
BY30-8/1-275
1
275
2
8
≤ 1.2
BY30-15/1-275
1
275
5
15
≤ 1.2
BY30-40/1-275
1
275
15
40
≤ 1.2
BY30-65/1-275
1
275
20
65
≤ 1.5
BY30-8/1-440
1
440
2
8
≤ 1.8
BY30-15/1-440
1
440
5
15
≤ 1.8
BY30-40/1-440
1
440
15
40
≤ 1.8
BY30-65/1-440
1
440
20
65
≤ 2.0
BY30-8/2-275
2
275
2
8
≤ 1.2
BY30-15/2-275
2
275
5
15
≤ 1.2
BY30-40/2-275
2
275
15
40
≤ 1.2
BY30-65/2-275
2
275
20
65
≤ 1.5
BY30-8/2-440
2
440
2
8
≤ 1.8
BY30-15/2-440
2
440
5
15
≤ 1.8
BY30-40/2-440
2
440
15
40
≤ 1.8
BY30-65/2-440
2
440
20
65
≤ 2.0
BY30-40/3-275
3
275
15
40
≤ 1.2
BY30-65/3-275
3
275
20
65
≤ 1.5
BY30-8/4-275
4
275
2
8
≤ 1.2
BY30-15/4-275
4
275
5
15
≤ 1.2
BY30-40/4-275
4
275
15
40
≤ 1.2
BY30-65/4-275
4
275
20
65
≤ 1.5
BY30-8/4-440
4
440
2
8
≤ 1.8
BY30-15/4-440
4
440
5
15
≤ 1.8
BY30-40/4-440
4
440
15
40
≤ 1.8
BY30-65/4-440
4
440
20
65
≤ 2.0
Technical Parameters
 
8-275
8-440
15-275
15-440
40-275
40-440
65-275
65-440
Maximum continuous operating voltage Uc
275V
440V
275V
440V
275V
440V
275V
440V
Nominal discharge current (8/20 µ s) In
2
2
5
5
15
15
20
20
Maximum discharge current (8/20 µ s) Imax
8
8
15
15
40
40
65
65
Voltage protection leve kV Up
≤ 1.2
≤ 1.8
≤ 1.2
≤ 1.8
≤ 1.2
≤ 1.8
≤ 1.5
≤ 2.0
Response time ns tA
<25ns
Fuse or Circuit-breaker
16Agl/Gg
25Agl/Gg
50Agl/Gg
80Agl/Gg
Operating temperature
-40℃~+80℃
Connection section
Min.1.5mm2, Max.35mm2
Installation  
35 mm Rail
Outer covering material
Reinforced fire-retardant nylon PBT
Defending grade
IP20

Frequently asked questions about the BY30 Surge Arrestor

What is the difference between an MCB and an MCCB?

An MCB (miniature circuit breaker) is a DIN-rail device for final circuits, typically rated up to 125 A with a fixed trip curve. An MCCB (moulded case circuit breaker) is a larger device for main and sub-main distribution, usually 16 A to 1600 A, with adjustable thermal and magnetic settings and a higher breaking capacity. Use an MCB for branch circuits and an MCCB where you need adjustability or higher fault ratings.

How do I choose between a Type B, C and D trip curve?

Type B trips between 3 and 5 times rated current and suits resistive loads such as lighting and heaters. Type C trips between 5 and 10 times and is the general-purpose choice for socket circuits and mixed loads. Type D trips between 10 and 20 times and is used for loads with high inrush, such as motors, transformers and large LED drivers.

What does 6 kA breaking capacity mean in practice?

It is the maximum prospective short-circuit current the device can safely interrupt. 6 kA covers most domestic and light commercial installations. Where the transformer is close and the fault level is higher, specify 10 kA devices so the breaker still clears the fault without damage.

Can these devices be supplied with your own brand?

Yes. OEM branding, buyer-specific labels, custom carton print and private-model numbering can be arranged on qualified order volumes.