Three groups output 120W switching power supply from the ELEHPD Multiple Series range.
The Three groups output 120W switching power supply is part of the ELEHPD Multiple Series range. Three groups output 120W switching power supply from the ELEHPD Multiple Series range. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
Full catalogue description: Three groups output 120W popular type switching power supply
| T-120W Triple output switching power supply | ||||
Model NO. | OUTPUT | Tolerance | range | efficiency |
| T-120A | 5V, 2-12A 12V, 0.5-5A -5V, 0.2-1A | ± 2% ± 6% ± 6% | 80mV 120mV 80mV | 77% |
| T-120B | 5V, 2-12A 12V, 0.5-5A -12V, 0.2-1A | ± 2% ± 6% ± 6% | 80mV 120mV 120mV | 77% |
| AC input voltage range | 85-132vac/170-264vac 47-63hz 240-370vdc | |||
| input current | 2.5A/115V 1.25A/230V | |||
| AC inrush current | Cold-start current 30A/115V 60A/230V | |||
| Leakage current | < 3.5mA/240VAC | |||
| DC adjustable range | ± 10% rated output voltage | |||
| over load protection | 105-150%cut down output, auto-recovery | |||
| over-voltage protection | 115-135% | |||
| set up, rise, hold up time: | 800ms, 20ms 20ms | |||
| withstand voltage: | I/P-O/P: 1.5KVAC 1Minutes I/P-FG: 1.5KVAC 1MInutes O/P-FG: 0.5VAC 1minutes | |||
| working temperature | -10~+60° C, 20-90%RH | |||
| weight/packing: | 0.9kg, 20pcs/18kg | |||
| Material | Aluminum | |||
| Size | 199*110*50M M | |||
| certificate | CE ISO9000 ROHS | |||
| Warranty year | 1 year | |||
| Protections | Short circuit / Over load / Over voltage |
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.