Global Trade · Reliable Power Solutions E-mail: [email protected]
Industrial Control › Multiple Series

50W three group output switching power supply

T-50A triple switching power supply Features:·AC input voltage range selected by switch ·Small volume,low weight,high efficie…

  • Category: Industrial Control › Multiple Series
  • Model: chance_116
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this Multiple Series

About the 50W three group output switching power supply

The 50W three group output switching power supply is part of the ELEHPD Multiple Series range. T-50A triple switching power supply Features:·AC input voltage range selected by switch ·Small volume,low weight,high efficiency ·Protections:short circuit/over load ·LED indicator for power on ·100% full load burn-in test ·2 Years warranty ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Full catalogue description: 50W three group output factory produced switching power supply

Typical applications

How to specify the right Multiple Series

  1. Size the contact rating for the inductive load, not just the resistive current (AC-3 duty for motors)
  2. Check the coil voltage and frequency available in the panel: 24 V DC, 110 V, 230 V or 400 V AC
  3. Confirm the auxiliary contact count needed for the control and indication circuit
  4. Match the enclosure rating to the environment (IP20 inside a panel, IP65 on the machine)

Specifications


50W three group output factory produced switching power supply

T-50A triple switching power supply

Features:·AC input voltage range selected by switch

·Small volume,low weight,high efficiency

·Protections:short circuit/over load

·LED indicator for power on

·100% full load burn-in test

·2 Years warranty

Model T-50A T-50B
Output DC Voltage Ch1:5v Ch2:12v Ch1:-5v Ch2:5v Ch1:12v Ch2:12v
Voltage tolerance ±2.0% ±6.0% ±6.0% ±2.0% ±6.0% ±6.0%
Rated Current 0.5-7A 0.2-1A 0-1A 0.5-7A 0.2-1A 0-1A
Related Power 50w 50w
Wave&Noise 80mVp-p 120mVp-p 80mVp-p 150mVp-p 120mVp-p 150mVp-p
DC Voltage ADJ range Ch1:-9%~+10%
Set up,rise,hold up time 200ms 100ms 30ms
Input Voltage Range 95 ~132VAC 180-264VAC 47-63HZ 120-370VDC
AC Current 1.6A/115VAC 0.8A/230VAC
Efficiency 72% 72%
AC inrush current Cold start current 20A/115V 40A /230VAC
Leakage current <3.5mA/240VAC
Protection Overload Related output power 105-150% start overload protection
Protection type: cutoff output, recovery after restart power
Over voltage Ch2 :115%~135%
Hiccup mode,recovers automatically after fault condition
Environment Working temp humidity -10~+60°C 20%~90%RH
Storage temp, humidity -20~+85°C 20%~90%RH Non-condensing
Withstand vibration 10-500Hz,2G 10min/1 cycle, period for 60min, each axes
Safety Withstand voltage I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolation resistance I/P-O/P:I/P-FG:O/P-FG: 100M Ohms/500VDC
Standard Safety standard Fit UL1012
Refer Design refer to GB4943,UL60950,EN60950
EMC standard Design refer to GB9254,EN55022 Class A
Size size L159*W98*H38mm
Package 0.54kg, 40pcs/22kg
Note:1.All parameters not specially mentioned are measured at 230VAC input, related load and 25 degree of ambient temperature.
2.Wave&noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.

Frequently asked questions about the 50W three group output switching power supply

What is the difference between a contactor and a relay?

A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.

How do I calculate the correct contactor size for a motor?

Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.

Do you supply the coil voltage I need?

Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.

Are auxiliary contacts included?

Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.

Related Multiple Series models