30W Three sets switching power supply T-30W triple output switching power supply Features:·AC input voltage range selected by switch…
The Three group power supply T-30 is part of the ELEHPD Multiple Series range. 30W Three sets switching power supply T-30W triple output switching power supply Features:·AC input voltage range selected by switch ·Small volume,low weight,high efficiency ·Protections:short circuit/over load ·LED indicator for power on ·100% full load burn-in test ·2 Years warranty ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
T-30W triple output switching power supply
Features:·AC input voltage range selected by switch
·Small volume,low weight,high efficiency
·Protections:short circuit/over load
·LED indicator for power on
·100% full load burn-in test
·2 Years warranty
| T-30W Triple output switching power supply | ||||
Model NO. | OUTPUT | Tolerance | range | efficiency |
| T-30A | 5V , 0.5-3A 12V, 0.1-1A -5V , 0.1-0.5A | ± 2% ± 2, -6% ± 2, -10% | 50mV 100mV 50mV | 70% |
| T-30B | 5V , 0.5-3A 12V, 0.1-A -12V, 0.1-0.5A | ± 2% ± 2, -6% ± 2% | 50mV 100mV 100mV | 72% |
| AC input voltage range | 85-132VAC/170-264VAC 47-63HZ 240-370VDC | |||
| input current | 2A/115V 1A/230V | |||
| AC inrush current | Cold-start current 18A/115V 36A/230V | |||
| Leakage current | < 0.5mA/240VAC | |||
| Over load protection | 105-150%cutdown output, auto-recovery | |||
| set up, rise, hold up time: | 800mS 20ms 70ms/230VAC | |||
| withstand voltage: | I/P-O/P: 1.5KVAC 1Minutes I/P-FG: 1.5KVAC 1MInutes O/P-FG: 0.5VAC 1minutes | |||
| working temperature | -10~+60° C | |||
| weight/packing: | 0.42kg 45PCS/19KG | |||
| Size | 129*98*38M M | |||
| certificate | CE ISO9000 ROHS | |||
| Warranty year | 1 year | |||
| Protections | Short circuit / Over load / Over voltage |
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.