Z3N-TB22 Color mark sensor color sensor Model list
The Z3N-TB22 Color mark sensor color sensor is part of the ELEHPD Color Mark Sensor range. Z3N-TB22 Color mark sensor color sensor Model list ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
Full catalogue description: Z3N-TB22 Color mark sensor color sensor packing sensor for machine
Model list
| Type | Light source | Cable | Type | Light source | cable |
| TR22 | Red | Four wire | TR2 | Red | Three wire |
| RG22 | green | Four wire | RG2 | green | Three wire |
| T22 | Red+green | Four wire | T2 | Red+green | Three wire |
| TB22 | Green+bule | Four wire | TB2 | Green+bule | Three wire |
| TW22 | Green-white | Four wire | TW2 | Green-white | Three wire |
specification
| Detecting method | Coaxial reflection |
| Detecting distance | 10mm±2mm |
| Supply Voltage | 10-30VDC |
| Current consumption | <45mA |
| Source chromatography | Red/green/blue |
| Light spot | M0.5 mm - M1.5 mm optional |
| Detecting angle | light should be vertical with the surface of detected object,allow deviation of ±15° |
| Response time | 0.1~1ms |
| Output method | NPN or PNP NO/NC |
| Indicator: | red led |
| Output voltage | (high)VS-(≤1.5) (low)(≤1.2V) |
| Load current | 200mA(max) |
| Circuit protection device | Reverse polarity protection,short circuit protection,Overcurrent protection,arbitrary line on the wrong protection. |
| Sensitivity | adjustble |
| Anti outside light | 10000Lux stage lighting,100000Lux sun light |
| protection Level | IP67(Moistureproof and dustproof) |
| Housing material | Aluminium |
| Cable | 2m PVC |
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.