Global Trade · Reliable Power Solutions E-mail: [email protected]
Industrial Control › MS Series

MS-60W mini type mini size MS series electric

Features: • Universal AC input / Full range • Protections:Short circuit/Over load/Over voltage • Cooling by free air convection • 100% full…

  • Category: Industrial Control › MS Series
  • Model: chance_197
  • Brand / OEM: ELEHPD — OEM branding available
  • Export: Worldwide, FOB Ningbo / Shanghai
Request a quotation for this MS Series

About the MS-60W mini type mini size MS series electric

The MS-60W mini type mini size MS series electric is part of the ELEHPD MS Series range. Features: • Universal AC input / Full range • Protections:Short circuit/Over load/Over voltage • Cooling by free air convection • 100% full load burn-in test • Fixed switching frequency at 77KHz • 2 years warranty Details ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.

Full catalogue description: mini type mini size MS series electric industry switching power supply MS series MS-60W

Typical applications

How to specify the right MS Series

  1. Size the contact rating for the inductive load, not just the resistive current (AC-3 duty for motors)
  2. Check the coil voltage and frequency available in the panel: 24 V DC, 110 V, 230 V or 400 V AC
  3. Confirm the auxiliary contact count needed for the control and indication circuit
  4. Match the enclosure rating to the environment (IP20 inside a panel, IP65 on the machine)

Specifications

mini type mini size MS series electric industry switching power supply MS series MS-60W

Features :

• Universal AC input / Full range

• Protections:Short circuit/Over load/Over voltage

• Cooling by free air convection

• 100% full load burn-in test

• Fixed switching frequency at 77KHz

• 2 years warranty

Details:

Model MS-60-5 MS-60-12 MS-60-15 MS-60-24
Output DC Voltage 5V 12V 15V 24V
Rated Current 12A 5A 4A 2.5A
Current Range 0~12A 0~5A 0~4A 0~2.5A
Rated Power 60W 60W 60W 60W
Ripple & Noise (max.) Note.2 120mVp-p 120mVp-p 150mVp-p 150mVp-p
Voltage Adj. Range 4.75~5.5V 10.8~13.2V 13.5~16.5V 21.6~26.4V
Voltage Tolerance Note.3 ±2.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±1.0% ±0.5% ±0.5% ±0.5%
Setup,Rise time 200ms 100ms
Hold time (Typ.) 30ms
Input Voltage Range 85 ~ 264VAC 120 ~ 370VDC
Frequency Range 47~63HZ
Efficiency(Typ.) 73% 76% 77% 79%
AC Current(Typ.) 2A/115VAC 1A/230VAC
Inrush Current (Typ.) COLD START 20A/115VAC 40A/230VAC
Leakage Current <0.5mA / 240VAC
Protection Over Load 105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Environment Working Temperature -10 ~ +60°c (Refer to "Derating Curve" )
Working Humidity 20~90% RH Non-condensing
Storage temp.& humidity -20~+85°C, 10~95%RH
Temp. coefficient ±0.03%/°C (0~50°C)
Vibration 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

Safety & EMC

(Note 4.)

Safety Standards UL1012, UL60950-1, TUV EN60950-1, CCC GB4943 approved
Withstand Voltage I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/ 25°c / 70% RH
EMC Emission Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
Others MTBF 522.1K hrs min. MIL-HDBK-217F (25 °c)
Dimension 111*78*36mm (L*W*H)
Packing 0.26Kg; 45pcs/15Kg/0.9CUFT
Note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°c of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.


Frequently asked questions about the MS-60W mini type mini size MS series electric

What is the difference between a contactor and a relay?

A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.

How do I calculate the correct contactor size for a motor?

Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.

Do you supply the coil voltage I need?

Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.

Are auxiliary contacts included?

Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.

Related MS Series models