Mini size switching power supply 250w MS-250W Features: • Universal AC input / Full range • Protections:Short circuit/Over load/Over voltag…
The MS-250W mini type mini size MS series electric 250W 5V 12V is part of the ELEHPD MS Series range. Mini size switching power supply 250w MS-250W Features: • Universal AC input / Full range • Protections:Short circuit/Over load/Over voltage • Cooling by free air convection • 100% full load burn-in test • Fixed switching frequency at 77KHz • 2 years warranty SPECIFICATION ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
Full catalogue description: mini type mini size MS series electric industry switching power supply MS-250W
Features :
• Universal AC input / Full range
• Protections:Short circuit/Over load/Over voltage
• Cooling by free air convection
• 100% full load burn-in test
• Fixed switching frequency at 77KHz
• 2 years warranty
| MODEL | MS-250-5 | MS-250-12 | MS-250-15 | MS-250-24 | MS-250-27 | MS-250-48 | |
| OUTPUT | DC voltage | 5V | 12V | 15V | 24V | 27V | 48V |
| Voltage tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
| Rated current | 40A | 20A | 16A | 10A | 9A | 5.2A | |
| Current range | 0~40A | 0~20A | 0~16A | 0~10A | 0~9A | 0~5.2A | |
| Rated power | 200W | 240W | 240W | 240W | 243W | 249.6W | |
| Ripple&noise | 150mvp-p | 150mvp-p | 180mvp-p | 180mvp-p | 180mvp-p | 200mvp-p | |
| DC voltage ADJ.range | -9%~+10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
| INPUT | Voltage range | 90~132VAC/180~264VAC(selected by switch),254~373VDC | |||||
| frequency | 47~63Hz | ||||||
| AC current | 4.5A/115VAC,2.5A/230VAC | ||||||
| efficiency | 82% | 84% | 84% | 85% | 85% | 86% | |
| Inrush current | Cold start current 25A/115VAC,40A/230VAC | ||||||
| Leakage current | < 2.5mA/240VAC | ||||||
| PROTECTION | overload | Rated output power110%~135% start over load protection | |||||
| protection type:hiccup mode,auto-recovery after fault condition is removed | |||||||
| Over voltage | 6.8~8.2V | 15.6~17.8V | 18.6~20.8V | 30.6~33.2V | 42.6~44.2V | 54.8~56.6V | |
| protection type:hiccup mode,auto-recovery after fault condition is removed | |||||||
| Over temperature | TSW1detect on heatsink of power transistor≥95ºC±5ºC, start over temperature protection | ||||||
| protection type:hiccup mode,auto-recovery after temperature become normal | |||||||
| ENVIROMENT | Working temp,humidity | -10ºC~+60ºC,20%~90%RH | |||||
| Storagetemp,humidity | -20ºC~+85ºC,10%~95%RH non-condensing | ||||||
| Withstand vibration | 10~500Hz,2G 10min/1cycle,period for 60 minutes,each axes | ||||||
| SAFETY STANDARD& EMC | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
| Isolated resistance | I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC | ||||||
| Safety standard | DESIGN REFER TO UL1012 | ||||||
| EMC standard | EN55022,CLASSA | ||||||
| OTHERS | Dimension | 199*99*48mm (L*W*H) | |||||
| Weight/packing | 0.7kg/24pcs/17.5kg/0.034 m³/1.2CUFT | ||||||
| NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.