CMF37 capacitance type cylinder type proximity from the ELEHPD Capacitance Type range.
The CMF37 capacitance type cylinder type proximity is part of the ELEHPD Capacitance Type range. CMF37 capacitance type cylinder type proximity from the ELEHPD Capacitance Type range. ELEHPD manufactures and exports low voltage electrical products from Yueqing, Zhejiang, China, supplying distributors, panel builders, M&E contractors and OEM buyers worldwide.
Full catalogue description: capacitance type cylinder type proximity sensor switch CMF37
PARAMETER DATA
| Flush | Detection distance | ||
| DC 6~36VDC | NPN | NO | |
| NC | |||
| NO+NC | |||
| PNP | NO | ||
| NC | |||
| NO+NC | |||
| two wire system | NO | ||
| NC | |||
| AC 90~250 VAC | SCR Control- lable silicon | NO | |
| NC | |||
| NO+NC | |||
| Relay output | |||
| Non- Flush | Detection distance | 0-25mm | |
| DC 10~30 VDC | NPN | NO | CMF37-25-DNA |
| NC | CMF37-25-DNB | ||
| NO+NC | |||
| PNP | NO | CMF37-25-DPA | |
| NC | CMF37-25-DPB | ||
| NO+NC | |||
| two wire system | NO | CMF37-25-DLA | |
| NC | |||
| AC 90~250 VAC | SCR Control- lable silicon | NO | CMF37-25-ACA |
| NC | CMF37-25-ACB | ||
| NO+NC | |||
| Relay output | |||
| Output current | DC | 200mA | |
| SCR/ Relay | 200mA | ||
| Output voltage dropDC/AC | DC<3V、AC<7V | ||
| Consumption current | DC<15mA, AC<10mA | ||
| Standard detected object | conductor and dielectric body | ||
| Repeated precision | 0.02 | ||
| DC/AC Response frequency | 400Hz/25Hz | ||
| Working environment temperature | -25°C~+70°C | ||
| Insulation resistance | |||
| Shell material | ABS Plastic | ||
| Protection grade | IP54 |
A contactor is built for switching power circuits repeatedly at high current, often with motor duty ratings (AC-3) and arc-suppressing chambers. A relay switches control signals at low current. In practice: contactor for the motor, relay in the control circuit that drives the contactor coil.
Use the motor's full-load current, apply the AC-3 rating for the operating voltage, and allow for the number of starts per hour. As a rule of thumb, the contactor's AC-3 rating should be at least equal to the motor FLC, then step up one frame if the duty is heavy.
Coil voltages are specified per order. Send the model number, coil voltage and frequency you require and we will confirm availability and lead time.
Base models come with the standard auxiliary contact configuration for that frame. Add-on auxiliary blocks and mechanical interlocks can be quoted with the contactor.