Float Switches & Level Control · Global Supply E-mail: [email protected]

OEM Float Switch Specification Sheet — UKY Cable Float Series

Free engineering tool: Float switch cable length & voltage drop calculator — interactive sizing tool plus an open CSV dataset (CC BY 4.0, embeddable).

A single reference page for purchasing and design teams evaluating a factory-direct, private-label float switch. Every value below comes from our current UKY product data (models 9001-9005); nothing here is a certificate claim.

1. Specification at a glance

ParameterValue
ProductUKY series cable float switch — sealed polypropylene body, steel ball and microswitch
Factory-fitted cable2 / 3 / 5 / 10 / 15 m (models 9001-9005)
Cable typeFlexible PVC or HO7RN-F, 3-core black / blue / brown
Rated voltage250 V AC, 380 V maximum isolation; 120 V AC versions for 110/120 V markets
Contact ratings16 A (8 A), 10 A (8 A) or 10 A (4 A) depending on version
ProtectionIP68CS — rated for permanent immersion
Rated temperature70 C (datasheet also states a 0-80 C working range; confirm the version when specifying)
EnduranceOver 100,000 mechanical cycles; over 50,000 electrical cycles
Switching levelAdjusted by sliding the polypropylene counterweight along the cable — no tools
WiringThe same 3-core float wires for pump-up (fill) or pump-down (empty) by reversing two cores
OEM options5 float shapes, 5 body colours, private-label markings and packaging, custom cable lengths
Typical mediaClean water, wastewater and light sewage in tanks, wells and pump-control panels

2. How it is wired

The float tilts as the level changes and operates an internal microswitch. With the 3-core black / blue / brown cable, the same unit can be wired for pump-up control (fill a tank, stop at high level) or pump-down control (empty a pit, stop at low level) by reversing two cores. Two or more units give independent start, stop and high-level alarm points. The switching level is set by sliding the counterweight along the cable, with no tools.

The float is a signal device. On three-phase or higher-power pumps it switches the contactor coil inside the control panel, not the motor directly. Fixed mains wiring should be done by a qualified electrician.

3. OEM / private-label supply

We supply OEMs, pump packagers, control-panel builders and distributors factory-direct: private-label markings and packaging, custom cable lengths, selected float shapes and colours, and an English datasheet plus wiring diagram for your part number. Russian-language documentation and Vietnamese labelling can be coordinated with the importer. Spares and documentation ship from the factory; we do not maintain local repair centres or spare-parts warehouses in the destination market.

4. Limits you should know before specifying

Standard models are not Ex / intrinsically safe. They are intended for clean water, wastewater and light sewage; highly viscous or heavily solids-laden media need a separate assessment. We do not claim WaterMark, AS/NZS 4020, EAC/GOST or Vietnamese CR certification on this page. Whether a finished assembly requires a local conformity mark depends on its HS code and the applicable regulation, and must be confirmed by the importer or panel builder for the complete assembly.

5. Request the datasheet or a quotation

Send three items — cable length, contact rating / supply voltage, and approximate quantity — and we will return the datasheet, wiring diagram and a factory-direct quotation. Use the contact form or reply to the email that brought you here.

Questions buyers usually ask

Can we order a private-label version with our own cable length?

Yes. The UKY range is supplied factory-direct with 2 / 3 / 5 / 10 / 15 m cables, selected float body shapes and colours, and private-label markings and packaging. Custom lengths and English datasheets are prepared against your part number. Vietnamese, Russian or other local-language labelling is coordinated with the importer.

Are these switches Ex rated or certified for drinking-water contact?

No. Standard UKY models are not Ex / intrinsically safe, and we do not claim WaterMark, AS/NZS 4020, EAC/GOST or a Vietnamese CR certificate on this page. Whether a finished assembly needs a local conformity mark depends on its HS code and regulation and must be confirmed by the importer or panel builder. Available technical files are supplied on request.

What do you need in order to quote?

Three items: the cable length, the contact rating / supply voltage, and the approximate quantity per order. A float switch is a signal device — on three-phase or high-power pumps it feeds the contactor coil inside the control panel, it does not switch the motor directly.